OBL PRO Series Use And Maintenance Manual page 26

Table of Contents

Advertisement

Pump capacity
Priming
Languages
Password
DATE & CLOCK
UNIT OF
MEASUREMENT
PROXIMITY
File: UT-5601
Copyright © - OBL Metering pumps - All rights reserved
MAXIMUM FLOW RATE
TEST VOLUME
ADJUSTMENT
TEST PRESSURE
DATE OF THE LAST TEST
PERFORMED
PRIMING TIME
IT EN ES FR NL RU DE TU
USER
ADMIN
DATE FORMAT (DD/MM/YY)
TIME FORMAT (24/12 H)
DATE
TIME
Flow Rate L/h and Gal/h.
Alarm activation with red display.
Moreover, you can set the test
pressure (for test purposes only).
Moreover, you can set the motor
phase current (depending on the
power) so that the system can block
the pump once this current value is
exceeded (table 8:motor short-circuit
alarm). The system saves the date of
the last test performed. NOTE: it is
good practice to calibrate the
pump every time process
conditions change (pressure,
manual adjustment value, etc.).
In this screen, you can enter the flow
rate or volume
obtained during
calibration. The maximum flow rate
set will never be exceeded in the
operating modes. The adjustment
value is displayed in the operating
screen.
Set the priming time and click start
to start the priming function. Press
stop to stop the priming function.
Select language
Set the 4-digit password for each
user (it blocks the parameter setting
of the operating modes) or
administrator (it blocks the access to
settings).
You can choose how you want to
display the date and time. These
data are added to the statistics
report.
Even the volume measurement units
are updated accordingly.
The proximity sensor (supplied)
verifies the correct operation of the
pump. The firmware stops the pump
if the number of strokes is equal to 0
25