SERIE SERIES MECHANICAL DIAPHRAGM METERING PUMPS SPRING RETURN JOB N° ENGLISH PUMP TYPE SHEET ELECTRIC ACTUATOR TYPE OVERALL DRAWING MB/MC 16 MB/MC Z-Z9 17 MECHANISM SECTIONAL DRAWINGS PUMPHEAD SECTIONAL DRAWING ENCLOSED ITEM SERIAL/No...
C A U T I O N ! INFORMATION FOR CUSTOMERS OBL s.r.l. welcome pumps despatched to our premises for servicing. Basic suggestion for pump cleaning MANDATORY REQUIREMENT A - Close terminal box cover and seal cable entry with PG plugs.
GENERAL CHARACTERISTICS DESCRIPTION OF THE PUMP Fig. 1 The OBL’s metering pumps “MB/MC” series are con- • trolled-volume reciprocating pumps. The crank gear is driven by an electric motor and the strokes per minute of the diaphragm are given by an integral, oil-splash-lubricated , endless screw/wormwheel reduction gear (fig.1).
0,24/037 63/71 0,24/037 63/71 DIAPHRAGM STRUCTURE DIAPHRAGM SECTIONAL VIEW • The OBL's unique (patented) mechanical diaphragm design ensures controlled volumetric displacement, giving Sectional view without Complete sectional view with plunger-like performances. plastic support ring. plastic support ring. Thus the flow rate is virtually unaffected by the working pressure variations.
INSTALLATION INSTRUCTIONS FOR A PROPER INSTALLATION Provide with adequate clearance areas and safe access for operation and mainte- • Fig. 6 ASSEMBLING AREA nance, in particular in front of the hydraulic side and of the adjustment knob (fig. 6). • If the pump is installed outdoors, a shelter is recommend, specially when the pump is equipped with electric actuators or other delicate devices.
WRONG RIGHT Fig. 7/B Wrong Right Irregular suction Wrong Right Right Wrong Suggested installation Wrong Suggested installation Acceptable installation SUCTION SIDE FILTER The installation of a filter on the suction side is always recommended, particularly when the liquid to be metered contains suspended particles. •...
SUCTION PIPING FOR VISCOUS LIQUIDS Specific technical information is required for the installation of pumps intended for • Table E metering viscous liquids. S.P.M. cp max execution "A" - For this kind of application we recommend stainless steel pumpheads. 2000 1500 - The suction piping must have an adequate diameter;...
SAFETY VALVE Fig. 11 ON OFF VALVE CAUTION ! Mechanical diaphragm metering pumps absolutely need the installation of a relief valve; a pressure higher than the rating plate value would SAFETY VALVE break the mechanism. The safety valve has to be installed immediately after the discharge connection, anyhow •...
INSTALLATION OF THE PRESSURE GAUGE In order to check if the metering pump operates correctly, it is essential to install a pres- • Fig. 13 sure gauge on the discharge line (fig. 13). DRAIN VALVE PRESSURE GAUGE The pressure gauge shows the actual working pressure of the metering pump. This •...
STARTUP BEFORE THE STARTUP BEFORE THE STARTUP VERIFY THE FOLLOWING CONDITIONS: • Make sure that the baseplate is made of steel, stable and even. Do not install the pump directly on a concrete foundation. • Fix the pump to the baseplate using the specific anchor holes in the pump feet. •...
• The suction hydrostatic head exceeds the discharge pressure: Increase the discharge pressure by means of a back pressure valve. (OBL, series 300). • Back pressure valve stuck in open position because of foreing matters, or pressure setting too low respect to the suction head: Check .
PREVENTIVE MAINTENANCE We suggest the purchasing of a series of essential details • Table G for the preventive maintenance of diaphragm pump head EXECUTION (HEAD BODY MATERIAL) (table G). A AISI 316L DENOMINATION POSITION PIECES NO. POSITION PIECES NO. DIAPHRAGM VALVE SEATS VALVE GUIDES VALVE...
OPERATING TROUBLES FLOW RATE LOWER THAN EXPECTED CAUSES SOLUTIONS • Air enters the suction piping through the fittings: Check. • Air trapped inside the pump: For a short while, keep flow rate to maximum . • Excessive suction head lift: Reduce it.
PUMP WITH ELECTRIC ADJUSTMENT OVERALL DRAWINGS MB MC • Motors: Threephase 0,20/0,30 kW - 230/400 V 50/60 Hz - 4 Poles - IP55 - CL F - IEC34-1 Special flange motor MANUAL ADJUSTMENT ADJUSTMENT READING • Singlephase 0,24/37 kW FLANGED 230 V - 50/60 Hz - 4 Poles CONNECT.
Page 20
MB MC MECHANISM Pumphead sectional drawings PP1 1 Head Construction Head Construction PP11 - SEAT: AISI 316 L - BALL: AISI 316 L PP32 - SEAT: INCOLOY 825 - BALL: HASTELLOY C-276...
METERING PUMPS MACHINE DIRECTIVE EUROPEAN COMMUNITY DIRECTIVE 98/37/CE AND SUBSEQUENT MODIFICATIONS GENERAL SAFETY NORMS Please read and save these instructions. INSTRUCTIONS ABOUT THE RESIDUAL RISKS ELIMINATION AND THE SAFETY AT WORK WARNING: 1 - INSTALLATION 3 - ELECTRICAL CONNECTIONS Do not start the pump without a - The pump has to be - For a proper connection of the electrical safety valve.
METERING PUMPS CE CONFORMITY DECLARATION OBL s.r.l. 20090 Segrate - MILANO - Via Kennedy, 12 - Tel. +39 02 269191 - Fax +39 2 2133893 - E mail: info@obl.it Modello/Model/Modele/Modell/Modelo/Modelo/Model/Model/Typ/Model/Malli/ S E R I E S MECHANICAL DIAPHRAGM MB/MC METERING PUMPS DICHIARAZIONE DI CONFORMITA’...