Red: incorrect operation and pump lock
-
The PRO KIT does not adjust the stroke of the metering pump (cf. Use and maintenance manual of
the Line Black pump, chap. 10.2).
The KIT PRO adjusts the ratio between maximum and minimum flow rate provided, as it adds the
possibility to vary the number of revs of the electric motor and adjust the pump's stroke. This way,
the turndown ratio can be of 500:1.
NOTE: The system does not automatically record every adjustment. Therefore,
the flow rate and volume indicated by the software may differ from those
actually provided, unless a calibration procedure is carried out (Table ) with
the new adjustment position.
2

MAIN COMPONENTS AND DIMENSIONS

As shown in the following figures, the KIT PRO consists of:
1. 1 enclosure containing the electronic control unit
2. 1 connection
3. 1 proximity sensor
4. 4 connectors with a 1-meter cable