Weekly
3.3 Partialisation
In the event that the required flow rate is 30% lower than the set flow rate during calibration, the
pump starts the partlialisation stage. This stage consists in:
1. Work stage, in which the pump runs at 30%
2. Pause stage
The duration of these two stages are calculated by the firmware so as to obtain the flow rate
required.
The minimum flow rate provided is 1% the maximum flow rate. The pump fails to start if this value
is not reached.
3.4 Settings
The setting menu is shown in Figure 12 and allows you to open all the functions described in Table
.
Table 7 Settings
Modes
Calibration
File: UT-5601
Copyright © - OBL Metering pumps - All rights reserved
SET A PROGRAM:
PROGRAM No.
DURATION
START TIME
CONSTANT FLOW RATE
VOLUME
DAYS OF ACTIVITY
ACTIVE PROGRAMS
Figure 12 Settings
Input parameters
TEST DURATION
MOTOR POWER
MAXIMUM MOTOR PHASE CURRENT
MOTOR FREQUENCY
This menu allows you to set the data
of each program (max 13 programs).
You can set the constant flow rate or
volume of constant flow rate to be
transferred, transfer duration, start
time, and days of activity.
We recommend not overlapping the
programs.
This menu shows the active
programs and allows you to activate
or deactivate them.
Description
This mode allows you to test the
pump's flow rate at the maximum
frequency. The pump capacity screen
appears at the end of the test.
24