FEMA ELECTRÓNICA . SERIES B . Models Bxx-C1
1.13.23 'Overrange / underrange' function
Counter
overrange
Counter
underrange
1.13.24 Left zeros function
Left zeros
1.13.25 Excitation voltage function
Vexc. control
22
Flash
To zero
To preset
Flash
To zero
To preset
With left zeros.
Without left zeros.
Vexc with error control
Vexc without error control
The 'Counter overrange' ('c.orG') and 'Counter under-
range' ('c.urG') parameters configure the behavior of the
instrument when reading is higher than '999999' (over-
range) or lower than '-199999' (underrange). Select 'FLSH'
to enter reading into flash mode. Select 'to_0' to apply a
reset to '0'. Select 'to_P' to apply a reset to preset value.
The 'Left zeros' ('L.ZEr') parameter controls the left zeros on
or off.
At the 'Vexc control' ('V.ctr') parameter select 'on' to acti-
vate the 'Err.8' message, when consumption requested to
the excitation voltage is higher than the current the instru-
ment can provide.