1.13.20 'Fast access' configuration menu

Tools
Key UP
Setpoint 1
('Fast access')
Setpoint 2
Setpoint 3
Memory of
maximum
Memory of
minimum
Memory of
cycles
Preset value

1.13.21 'On power up' configuration menu

On power-up
Delay
Reset

1.13.22 'Key LE' configuration menu

Key LE
Seconds
No function
Front reset
Alarm unlock
Reset and alarm unlock
FEMA ELECTRÓNICA . SERIES B . Models Bxx-C1
At the 'Key UP ('fast access')' ('K.uP') menu configure
which functions and parameters will be accessible through
the 'fast access' menu. Select 'on' to activate each func-
tion. For more information see section 1.13.17.
• the 'Setpoint 1' ('ALr1') function allows to visualize
and modify the alarm 1 setpoint through the 'fast ac-
cess' menu.
• the 'Setpoint 2' ('ALr2') function allows to visualize
and modify the alarm 2 setpoint through the 'fast ac-
cess' menu.
• the 'Setpoint 3' ('ALr3') function allows to visualize
and modify the alarm 3 setpoint through the 'fast ac-
cess' menu.
• the 'Memory of maximum' ('MAX') or 'Memory of
minimum' ('MIn') functions allow to visualize the maxi-
mum or minimum reading value stored in memory.
• the 'Memory of cycles' ('cYcL') function allows to vi-
sualize the number of cycles value stored in memory.
The cycles value increases '+1' with each reset or preset
associated to the alarm activation or resets associated
to 'overrange' / 'underrange'.
• the 'Preset value' ('PrSt') function allows to visualize and
modify the preset value through the 'fast access' menu.
The 'On Power Up' ('on.Pu') menu assigns functions to be applied
when the instrument starts after a power loss. For more informa-
tion see section 1.13.18.
• at the 'Delay' ('dLAy') parameter configure the time the in-
strument will wait before starting normal functionality. Time
between 0 and 200 seconds.
• at the 'Reset' ('rSt') parameter set to 'on' to activate a re-
set when restarting after a power loss
The 'LE' (3) key at the front of the instrument can be
configured to activate several functions. For more infor-
mation see section 1.13.19.
• the 'No function' ('nonE') value assigns no function.
• the 'Front reset' ('F.rSt') value assigns the reset func-
tion.
• the 'Alarm unlock' ('A.Lck') value assigns the manual
alarm unlocking, when the 'Locked alarms' ('A.Lck')
function is active.
• the 'Reset and alarm unlock' ('Fr.AL') value assigns
both functions at the same key..