Fema Electronica S40 Series User Manual

Fema Electronica S40 Series User Manual

Panel meter 72x36mm size for truerms ac voltages / for truerms ac currents
Hide thumbs Also See for S40 Series:

Advertisement

Quick Links

Series S40
Panel Meters
Panel meter 72x36mm size
Model S40-A
Panel meter for TrueRMS measures of AC voltages and AC currents. Category
of measure in CAT-III up to 300Vac and CAT-II up to 600Vac. Current measures
up to 5Aac. Measure coupling selectable in AC or AC+DC. Instrument with
reduced housing size with standard 14mm digit height. Included "measure"
function (visualization of signal input without scaling), automatic signal correction,
peak&hold, double setpoint alarms, brightness control, filters, ... Universal power
options in AC and DC, signal retransmission and control options.
USER'S MANUAL
(1575R00)
for TrueRMS AC Voltages
for TrueRMS AC Currents

Advertisement

Table of Contents
loading

Summary of Contents for Fema Electronica S40 Series

  • Page 1 Series S40 Panel Meters Panel meter 72x36mm size Model S40-A for TrueRMS AC Voltages for TrueRMS AC Currents Panel meter for TrueRMS measures of AC voltages and AC currents. Category of measure in CAT-III up to 300Vac and CAT-II up to 600Vac. Current measures up to 5Aac.
  • Page 2: Order Reference

    User’s Manual S40-A Meter S40-A Panel meter 72x36mm size for TrueRMS VAC and AAC Panel meter for TrueRMS measure of AC voltages and AC Management for up to 4 alarms with 1 or 2 setpoints each, currents. Category of measure in CAT-III up to 300Vac and with hysteresis and delays.
  • Page 3: Power Connections

    User’s Manual S40-A Front View Input signal connections - AC Current The current measuring has a single jumper position. Select Alarms the input range in the configuration menu. 1 2 3 4 5 Jumpers for input signal range selection. See Table 1 1 2 3 4 Range Close Jumpers...
  • Page 4: Technical Data

    User’s Manual S40-A Technical Data Technical Data (cont.) Digits Power Type 7 segments, red Power “H” 85 to 265 Vac/dc Height 14 mm Power “L” 11 to 60 Vdc and 24/48Vac Display maximum 9999 Consumption <4W Display minimum -1999 Isolation 3500Veff for power “H”...
  • Page 5: Mechanical Dimensions (Mm)

    User’s Manual S40-A Mechanical Dimensions (mm) Information Menu Signal Range Configuration Input Low Display Low Panel 32,5 cut-out Input High Display High Information Menu - Operation Memory of maximum Maximum To enter the “Information Menu” press the SQ button. The “Information Menu”...
  • Page 6: Configuration Menu

    User’s Manual S40-A Configuration Menu Configuration Menu - Operation To enter the “Configuration Menu” press the SQ button. The Range 600Vac “Configuration Menu” allows to change the configuration of Input the instrument. Access to the “Configuration Menu” can be Range 100Vac password protected with the function “PASSWord”.
  • Page 7: Default Factory Configuration

    User’s Manual S40-A Configuration Menu Setpoint2 Second setpoint Tools Password Select password See menu for Alarm1 Factory Default Resets to factory de- See menu for Alarm1 fault values See menu for Alarm1 Firmware version Version Fixed Digits Fix digits Display Minimum brightness Brightness Default brightness...
  • Page 8: Input Menu

    User’s Manual S40-A Setpoint (SEt) - Value from “9999” to “-1999”. Alarm set point. Input Menu Hysteresis (hySt) - Value from “0” to “9999”. Points of hyster- The input menu selects the input signal range. Options avail- esis. The hysteresis applies on the deactivation of the alarm. able are 600Vac, 100Vac, 10Vac, 1Vac, 100mVac, 5Aac and 1Aac.
  • Page 9: Tools Menu

    User’s Manual S40-A Peak & Hold (P.hLd) - Peak & Hold function detects sharp Messages and errors drops in the displayed value, and holds the display if a display drop is detected. To disable the hold function for a moment, When the instrument detects that the displayed value does press any of the front buttons or wait for a predefined time : not correspond to the input value, the display will flash and...
  • Page 10: Accessing The Instrument

    User’s Manual S40-A Option R1 - 1 relay Accessing the instrument Relay type 3 contacts (Com, NC, NO) You may need to access the inside of the instrument to insert Maximum current 8A (resistive load) additional options. Use a flat screwdriver to unlock the upper Voltage 250 Vac continuously clips marked with “A”.
  • Page 11 User’s Manual S40-A FEMA ELECTRÓNICA - Page 11...
  • Page 12 other products Panel Meters Panel Meters Panel Meters Standard 96x48mm Small 72x36mm Miniature 48x24mm Large Displays Signal Converters Panel Meters 60&100mm digit & Isolators Standard 96x48mm www.fema.es ELECTRONIC INSTRUMENTATION FOR INDUSTRY FEMA ELECTRÓNICA, S.A. Altimira 14 - Pol. Ind. Santiga E08210 Barberà...