1.13.6 Counter + inhibition 'cn.3' configuration menu

Multiplier
Counter +
inhibition conf.
Divider
Preset
Mode
Inhibition

1.13.7 Counter + control add / subtract 'cnc.4' configuration menu

Multiplier
Counter + control
add / subtract conf.
Divider
Preset
Control A/S

1.13.8 Differential counter 'cnd.5' configuration menu

Multiplier
Differential
counter conf.
Divider
Preset
Configuration menu for mode 'counter + control inhibition'
Multiplier
('cnI.3'). Total impulses received are multiplied by the value
1 to 999999
of the 'multiplier' ('MuLt') parameter and divided by the 'di-
Divider
vider' ('dIV') parameter. Result is shown on the display.
1 to 999999
• set the 'Multiplier' ('MuLt') parameter from 1 to 999999.
Preset value
• set the 'Divider' ('dIV') parameter from 1 to 999999.
-199999 to 999999
• set the 'Preset' ('PrSt') parameter from -199999 to 999999.
Activate the reset to load the preset value on display.
Increasing
• at the 'Mode' ('ModE') parameter select 'uP' to count up-
Decreasing
wards (impulses increase the counter) or select 'doWn' to
count downwards (impulses decrease the counter).
Inhibits if channel
• at the 'inhibition' ('Inh') parameter select 'on_h' to inhibit
'B' to high
the counter when channel 'B' is active (logical state '1') or se-
Inhibits if channel
lect 'on_0' to inhibit the counter when channel 'B' is inactive
'B' to low
(logical state '0').
Configuration menu for mode 'counter + control add / sub-
Multiplier
tract' ('cnc.4'). Total impulses received are multiplied by the
1 to 999999
value of the 'multiplier' ('MuLt') parameter and divided by
Divider
the 'divider' ('dIV') parameter. Result is shown on the display.
1 to 999999
• set the 'Multiplier' ('MuLt') parameter from 1 to 999999.
• set the 'Divider' ('dIV') parameter from 1 to 999999.
Preset value
-199999 to 999999
• set the 'Preset' ('PrSt') parameter from -199999 to 999999.
Activate the reset to load the preset value on display.
Adds if channel 'B'
• at the 'Control A/S' ('Add') parameter select 'on_h' increase
to high
the counter with impulses received at channel 'A' when chan-
Subtracts if chan-
nel 'B' is active (logical state '1') or select 'on_0' to decrease
nel 'B' to low
the counter with impulses received at channel 'A' when chan-
nel 'B' is inactive (logical state '0').
Configuration menu for mode 'differential counter' ('cnd.5').
Multiplier
Total impulses received are multiplied by the value of the
1 to 999999
'multiplier' ('MuLt') parameter and divided by the 'divider'
Divider
('dIV') parameter. Result is shown on the display.
1 to 999999
• set the 'Multiplier' ('MuLt') parameter from 1 to 999999.
• set the 'Divider' ('dIV') parameter from 1 to 999999.
Preset value
-199999 to 999999
• set the 'Preset' ('PrSt') parameter from -199999 to 999999.
Activate the reset to load the preset value on display.
Impulses received on channel 'A' add to the counter. Impuls-
es received on channel 'B' subtract from the counter.
FEMA ELECTRÓNICA . SERIES B . Models Bxx-C1
13

Advertisement

Table of Contents
loading