Fema Electronica S40-R User Manual

Fema Electronica S40-R User Manual

Panel meter 72x36mm for ratiometric signals for potentiometers up to 5m
Hide thumbs Also See for S40-R:

Advertisement

Quick Links

Series S40
Panel Meters
Model S40-R
Panel meter for
signals. Accepts potentiometers up to 5 MOhm and from 200 Ohm
reduced housing size with standard 14mm digit height. excitation voltage for
transducers. Includes "measure" function (signal input visualization), peak&hold,
double setpoint alarms, brightness control, filters, ... Universal power options in
AC and DC, signal retransmission and control options (relay outputs, analogue
outputs, ...).
USER'S MANUAL
(2704R00)
Panel meter 72x36mm
for Ratiometric signals
for Potentiometers up to 5M
ratiometric and potentiometer signals
.
Accepts 3 wire ratiometric
. Instrument with

Advertisement

Table of Contents
loading

Summary of Contents for Fema Electronica S40-R

  • Page 1 Series S40 Panel Meters Panel meter 72x36mm Model S40-R for Ratiometric signals for Potentiometers up to 5M Panel meter for ratiometric and potentiometer signals Accepts 3 wire ratiometric . Instrument with signals. Accepts potentiometers up to 5 MOhm and from 200 Ohm reduced housing size with standard 14mm digit height.
  • Page 2: Order Reference

    User’s Manual S40-R Meter S40-R Panel meter 72x36mm for ratiometric and potentiometer signals Panel meter for ratiometric and potentiometer signals, from 3 password, brightness control, function “measure” for visual- wire transducers. The meter provides +5V (max. 35mA) and ization of input signal without scaling, offset and signal high a 0V signal, and receives from the transducer a signal be- autocorrection and “peak&hold”...
  • Page 3: Signal Connections

    User’s Manual S40-R Front View Signal Connections Alarms 1 2 3 Vexc +5V Ratiometric transducer or potentiometer 3 wires Signal Common Logo Button Button Button Units Rear View Option1 Option2 Example of ratiometric Example of ratiometric transducer for pressure. transducer for length.
  • Page 4: Technical Data

    User’s Manual S40-R Technical Data Technical Data (cont.) Digits Peak & Hold Type 7 segments, red Double setpoints Height 14 mm Brightness control yes, 5 levels Display maximum 9999 Display minimum -1999 Thermal stability Decimal point selectable 8.8.8.8. offset 10 ppm/ºC...
  • Page 5: Information Menu

    User’s Manual S40-R Information Menu Operating the Information Menu To enter the “Information Menu” press the SQ button. The “Information Menu” allows to visualize information and does Range (Rat.,Pot<5K, Pot<5M) not allow to modify the configuration of the instrument. It is Configuration not affected by the “PASSWord”...
  • Page 6: Configuration Menu

    User’s Manual S40-R Configuration Menu Ratiometric signal See menu for Alarm1 Input Potentiometer <5K Potentiometer <5M Value in KOhm Display Scaling Input Low Fixed Digits Fix digits Display Low Input High Average Display High Press LE to change selection Decimal Point...
  • Page 7: Default Factory Configuration

    User’s Manual S40-R Configuration Menu Tools Advanced Points Input0 Display0 display (Segment linearization) Input10 Display10 Enter signal values (“Input”) and associated display val- ues (“Display“) for each linearization point. Then activate “Act” to “On”. In case of error verify the points data.
  • Page 8: Input Menu

    User’s Manual S40-R Setpoint (SEt) - Value from “9999” to “-1999”. Alarm set point. Input Menu Hysteresis (hySt) - Value from “0” to “9999”. Points of hyster- The “input” menu selects the input signal range. Options are : esis. The hysteresis applies on the deactivation of the alarm.
  • Page 9: Tools Menu

    User’s Manual S40-R Peak & Hold (P.hLd) - Peak & Hold function detects sharp the activation delay and the value of setpoint2 (“Off” or the drops in the displayed value, and holds the display if a display setpoint2 value). drop is detected. To disable the hold function for a moment, press any of the front buttons or wait for a predefined time : OptionX (OptX) - Type of module installed.
  • Page 10 User’s Manual S40-R Option R1 - 1 relay Option AO - 1 analogue output Module with 1 relay. Up to 2 modules R1 can be installed Isolated analogue output, configurable for 4/20mA or in one S40 instrument. For more relay output needs, check 0/10Vdc.
  • Page 11: Warranty

    User’s Manual S40-R Warranty Accessing the instrument You may need to access the inside of the instrument to insert All instruments are warranted against all manufacturing additional options. Use a flat screwdriver to unlock the upper defects for a period of 24 MONTHS from the shipment date.
  • Page 12 other products Panel Meters Panel Meters Panel Meters Standard 96x48mm Small 72x36mm Miniature 48x24mm Large Displays Signal Converters Panel Meters 60&100mm digit & Isolators Standard 96x48mm www.fema.es ELECTRONIC INSTRUMENTATION FOR INDUSTRY FEMA ELECTRÓNICA, S.A. Altimira 14 - Pol. Ind. Santiga E08210 Barberà...