Emergency Stop Sense Input (Tb102); Figure 2-7: Estop Sense Input (Tb102); Table 2-11: Tb102B Estop Pinout; Table 2-12: Electrical Noise Suppression Devices - Aerotech Nmark SSaM Manual

Table of Contents

Advertisement

Nmark SSaM Hardware Manual

2.4.1. Emergency Stop Sense Input (TB102)

The ESTOP sense input is used to monitor the state of an external safety circuit only. This state is indicated
by the software and may be used to facilitate system restart. This ESTOP sense input is not intended to be a
complete safety system.
W A R N I N G :  The user is responsible for assessing operator risk levels and designing the
external safety circuits appropriately.
The ESTOP input is scaled for an input voltage of 5-24 volts.
If the ESTOP bit is enabled in the FaultMask axis parameter, the ESTOP input must be driven to prevent the
ESTOP fault condition.
Table 2-11:
TB102B ESTOP Pinout
Pin #
Label Description
7
ES+
Emergency Stop Digital Input +
8
ES-
Emergency Stop Digital Input -
N O T E :  Connecting the ESTOP input to a relay or other noise producing device requires the use of noise
suppression devices such as those in
suppress transient voltages.
Table 2-12:
Electrical Noise Suppression Devices
Device
RC (.1uf / 200 ohm) Network
Varistor
www.aerotech.com
Figure 2-7:
ESTOP Sense Input (TB102)
Table
2-12. These devices are applied across the switched coil to
Aerotech P/N
EIC00240
EID00160
Chapter 2
Installation and Configuration
Third Party P/N
Electrocube RG1782-8
Littelfuse V250LA40A
In/Out/Bi
Input
Input
29

Advertisement

Table of Contents
loading

Table of Contents