Victron energy MPPT 150/70 Manual page 64

Solar charger
Hide thumbs Also See for MPPT 150/70:
Table of Contents

Advertisement

Dimensions (h x w x d)
STANDARDS
Safety
1a) The solar charger will limit input power if more PV power is connected.
1b) The PV voltage must exceed Vbat + 5V for the controller to start. Thereafter the minimum PV voltage is Vbat + 1V.
2) A higher short circuit current may damage the solar charger in case of reverse polarity connection of the PV array.
3) Maximum current per MC4 connector is 30A.
4) Equalization is by default disabled.
5) For more information on data communication see the
our website.
6) MC4 models: several splitter pairs may be needed to parallel the strings of solar panels. The MC4 connectors are
internally parallel connected to a single MPPT tracker.
Page 60
MPPT solar charger manual
250/70
Tr models: 185 x 250 x
95mm
MC4 models: 215 x 250 x
95mm
EN/IEC 62109-1, UL 1741, CSA C22.2
data communication paper
250/85
250/100
Tr models: 216 x 295 x 103mm
MC4 models: 246 x 295 x 103mm
in the
Technical information section
Technical specifications
on

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Mppt 150/85Mppt 150/100Mppt 250/70Mppt 250/85Mppt 250/100Smartsolar mppt 150/60 ... Show all