Sign In
Upload
Manuals
Brands
Victron energy Manuals
Controller
MPPT Control
Victron energy MPPT Control Manuals
Manuals and User Guides for Victron energy MPPT Control. We have
4
Victron energy MPPT Control manuals available for free PDF download: Owner's Manual, Manual
Victron energy MPPT Control Owner's Manual (154 pages)
solar charger
Brand:
Victron energy
| Category:
Battery Charger
| Size: 16 MB
Table of Contents
Deutsch
2
Table of Contents
2
Sicherheitsvorkehrungen
5
Allgemeine Sicherheitshinweise
5
Sicherheitshinweise zur Verkabelung
5
Einführung
7
Batteriespannung, PV-Spannung und Nennstrom
7
TR oder MC4-Modelle
7
Eigenschaften
8
Automatische Batteriespannungserkennung
8
Hervorragender MPPT-Algorithmus
8
Hervorragender Wirkungsgrad
8
Umfassender Elektronischer Schutz
8
Victronconnect App
8
Ve.can-Anschlüsse
10
Ve.direct Anschluss
10
Display
10
Laden der Batterie
11
Adaptive 3-Stufige Aufladung der Batterie
11
Flexible Ladealgorithmen
11
Ausgleichsladung
11
Temperaturerfassung
11
Externer Temperatur- und Spannungssensor
12
Interner Temperatursensor
12
Spannungsmessung
13
Ferngesteuerte Ein-/Aus-Schaltung
13
Programmierbares Relais
13
Wirebox
13
Installation
14
Montage
14
Batterie
14
PV-Anlage
14
Elektrische Verbindungen
16
Erdung
16
Installation der Optionalen Smartsolar Control-Display
17
Anschluss des MPPT Control-Displays
18
Konfiguration und Einstellungen
19
Einstellungen Ändern
19
Einstellungen über die Victronconnect App
19
Einstellungen über den Drehschalter
20
Einstellungen über das Smartsolar Control-Display
21
Einstellungen über das MPPT Control-Display
21
Erklärung aller Einstellungen
22
Batterieeinstellungen
22
Einstellungen Lastausgang
28
Einstellungen des Programmierbaren Relais
29
Einstellungen der Straßenbeleuchtung
31
Einstellungen des TX-Ports
34
Einstellungen des RX-Ports
35
Aktualisierung der Firmware
36
Deaktivieren und Aktivieren von Bluetooth
36
Ve.smart-Netzwerk
37
Einrichtung des Ve.smart-Netzwerks
38
Betrieb
41
Start
41
Laden der Batterie
41
Automatischer Zellenausgleich
42
Lithium-Batterien
42
Herunterfahren und Neustart
42
Wartungsablauf
43
Überwachung
44
LED-Anzeigen
44
Fehlercodes
45
Überwachung über die Victronconnect App
45
Victronconnect-Statusbildschirm
45
Victronconnect-Verlaufsbildschirm
46
Victronconnect-Fehlerprotokollierung
47
Überwachung über ein GX-Gerät und das VRM
47
Gewährleistung
49
Fehlersuche und Support
50
Der Regler ist nicht Betriebsbereit
50
Sichtprüfung
50
Überprüfung der Batterieversorgung
50
Batterien werden nicht Geladen
51
Verpolung der Batterie
51
Vertauschte PV-Polarität
52
Batterie Voll
52
Fernsteuerungsklemme Fehlt, ist Abgeklemmt oder Externe Steuerung ist Aktiv
52
Das Ladegerät ist Deaktiviert
53
PV-Spannung zu Niedrig
53
Einstellung der Batteriespannung zu Niedrig
54
Batterieversorgungsprobleme
55
Von einem Externen Gerät Gesteuert
55
PV-Spannung zu Hoch
56
Batterien sind nicht Ausreichend Aufgeladen
57
Zu Hohe DC-Last
57
Batterieladespannungen sind zu Niedrig
57
Die Batterie ist Fast Voll
57
Spannungsabfall IM Batteriekabel
57
Temperaturunterschied zwischen Solarladegerät und Batterie
58
Unzureichende Solarleistung
59
Falsche Einstellung des Temperaturausgleichs
59
Batterieladestrom zu Niedrig
59
Batterien sind Überladen
59
Batterie nicht für die Ausgleichsregelung Geeignet
60
Batterie Alt oder Defekt
60
Batterieladespannungen zu Hoch
60
Batteriespannung zu Hoch Eingestellt
60
Solarprobleme
61
PV-Rückstrom zu Hoch
61
PV-Ertrag Geringer als Erwartet
61
Volle Nennleistung nicht Erreicht
62
Die Maximale PV-Ausgangsleistung Bezieht sich auf die Batteriespannung
63
Gemischte PV-Paneltypen
63
PV-Anschlüsse Verbrannt oder Geschmolzen
63
Kommunikationsprobleme
64
Kommunikationsprobleme mit dem Ve.direct-Anschluss
64
Victronconnect-Probleme
64
Kommunikationsprobleme mit dem Ve.can-Anschluss
64
Erdstrom
64
Optimierer können nicht Verwendet werden
64
MC4-Stecker Falsch Angeschlossen
64
Erdschlusserkennung Fehlt
64
Kommunikationsprobleme mit dem Ve.smart-Anschluss
65
Bluetooth-Probleme
65
Einstellungs- oder Firmware-Probleme
66
Falsche Einstellungen
66
Firmware-Probleme
66
Kann nicht als DC/DC-Ladegerät Betrieben werden
67
Probleme mit dem Relais
67
Probleme Beim Betrieb
67
Kann nicht als Stromquelle Betrieben werden
67
Unterbrochenes Firmware-Update
67
Technische Angaben
69
Anhang
73
Maße 70A-MC4-Ve.can
73
Maße 70A-Tr-Ve.can
74
Maße 85A-MC4-Ve.can und 100A-MC4-Ve.can
74
Maße 85A-Tr-Ve.can und 100A-Tr-Ve.can
75
Übersicht der Fehlercodes des Ladegeräts
76
English
81
General Safety Precautions
84
Safety Precautions
84
Wiring Safety Precautions
84
Battery Voltage, PV Voltage and Current Rating
86
Introduction
86
TR or MC4 Model
86
Automatic Battery Voltage Detection
87
Extensive Electronic Protection
87
Features
87
Outstanding Conversion Efficiency
87
Outstanding MPPT Algorithm
87
Victronconnect App
87
Display
88
Adaptive 3-Stage Battery Charging
89
Battery Charging
89
Ve.can Ports
89
Ve.direct Port
89
Equalization Charging
90
External Temperature and Voltage Sensor
90
Flexible Charge Algorithm
90
Internal Temperature Sensor
90
Temperature Sensing
90
Programmable Relay
91
Remote On/Off
91
Voltage Sensing
91
Wirebox
92
Battery
93
Installation
93
Mounting
93
PV Array
93
Grounding
94
Electrical Connections
95
Install the Optional Smartsolar Control Display
96
Connect the MPPT Control Display
97
Configuration and Settings
98
How to Change Settings
98
Settings Via the Rotary Switch
98
Settings Via the Victronconnect App
98
Settings Via the Smartsolar Control Display
100
All Settings Explained
101
Battery Settings
101
Load Output Settings
106
Programmable Relay Settings
107
Streetlight Settings
109
TX Port Settings
112
RX Port Settings
113
Disabling and Enabling Bluetooth
114
Updating Firmware
114
Ve.smart Network
115
Ve.smart Network Setup
116
Battery Charging
119
Operation
119
Start up
119
Automatic Equalization
120
Lithium Batteries
120
Shutdown and Restart Procedure
120
Maintenance Procedure
121
LED Indications
122
Monitoring
122
Error Codes
123
Monitoring Via the Victronconnect App
123
Victronconnect Status Screen
123
Victronconnect History Screen
124
Monitoring Via a GX Device and VRM
125
Victronconnect Error Reporting
125
Warranty
127
Battery Supply Check
128
The Controller Is Not Operational
128
Troubleshooting and Support
128
Visual Check
128
Batteries Are Not Charged
129
Reverse Battery Polarity
129
Battery Full
130
Remote Terminal Is Missing, Is Disconnected or External Control Is Active
130
Reverse PV Polarity
130
PV Voltage too Low
131
The Charger Is Disabled
131
Battery Voltage Setting too Low
132
Controlled by an External Device
132
Battery Supply Issue
133
PV Voltage too High
133
Batteries Are Undercharged
134
Battery Charge Voltages Are too Low
134
The Battery Is Almost Full
134
Too Much DC Load
134
Battery Cable Voltage Drop
135
Battery Charge Current too Low
136
Insufficient Solar
136
Temperature Difference between Solar Charger and Battery
136
Wrong Temperature Compensation Setting
136
Batteries Are Overcharged
137
Battery Charge Voltages too High
137
Battery Old or Faulty
137
Battery Unable to Deal with Equalization
137
Battery Voltage Setting too High
137
PV Reverse Current too High
138
PV Yield Less than Expected
138
Solar Issues
138
Full Rated Output Not Reached
139
Max PV Output Power Relates to Battery Voltage
140
Mixed PV Panel Types
140
PV Connections Burned or Melted
140
Communication Issues
141
Earth Fault Detection Missing
141
Ground Current
141
MC4 Connectors Wrongly Connected
141
Optimisers Cannot be Used
141
Ve.can Port Communication Issues
141
Ve.direct Port Communication Issues
141
Victronconnect Issues
141
Bluetooth Issues
142
Ve.smart Communication Issues
142
Firmware Issues
143
Incorrect Settings
143
Settings or Firmware Issues
143
Interrupted Firmware Update
144
Operation Issues
144
Relay Issues
144
Unable to Operate as a DC to DC Charger
144
Unable to Operate as a Power Supply
144
Technical Specifications
145
Appendix
149
Dimensions 70A-MC4-Ve.can
149
Dimensions 70A-Tr-Ve.can
150
Dimensions 85A-MC4-Ve.can and 100A-MC4-Ve.can
150
Dimensions 85A-Tr-Ve.can and 100A-Tr-Ve.can
151
Charger Error Code Overview
152
Advertisement
Victron energy MPPT Control Manual (70 pages)
solar charger
Brand:
Victron energy
| Category:
Battery Charger
| Size: 8 MB
Table of Contents
Table of Contents
2
1 Safety Precautions
5
General Safety Precautions
5
Wiring Safety Precautions
5
2 Introduction
7
Battery Voltage, PV Voltage and Current Rating
7
TR or MC4 Model
7
3 Features
8
Automatic Battery Voltage Detection
8
Outstanding MPPT Algorithm
8
Outstanding Conversion Efficiency
8
Extensive Electronic Protection
8
Victronconnect App
8
Display
9
Ve.direct Port
10
Ve.can Ports
10
Battery Charging
10
Adaptive 3-Stage Battery Charging
10
Flexible Charge Algorithm
11
Equalization Charging
11
Temperature Sensing
11
Internal Temperature Sensor
11
External Temperature and Voltage Sensor
11
Voltage Sensing
12
Remote On/Off
12
Programmable Relay
12
Wirebox
12
4 Installation
14
Mounting
14
Battery
14
PV Array
14
Grounding
15
Electrical Connections
16
Install the Optional Smartsolar Control Display
17
Connect the MPPT Control Display
18
5 Configuration and Settings
19
How to Change Settings
19
Settings Via the Victronconnect App
19
Settings Via the Rotary Switch
19
Settings Via the Smartsolar Control Display
21
Settings Via MPPT Control Display
21
All Settings Explained
21
Battery Settings
22
Load Output Settings
27
Programmable Relay Settings
28
Streetlight Settings
29
TX Port Settings
32
RX Port Settings
33
Updating Firmware
34
Ve.smart Network
34
Ve.smart Network Setup
35
6 Operation
37
Start up
37
Battery Charging
37
Automatic Equalization
38
Lithium Batteries
38
Shutdown and Restart Procedure
38
Maintenance Procedure
39
7 Monitoring
40
LED Indications
40
Error Codes
41
Monitoring Via the Victronconnect App
41
Victronconnect Status Screen
41
Victronconnect History Screen
42
Victronconnect Error Reporting
43
Monitoring Via a GX Device and VRM
43
8 Warranty
44
9 Troubleshooting and Support
45
The Controller Is Not Operational
45
Visual Check
45
Battery Supply Check
45
Batteries Are Not Charged
46
Reverse Battery Polarity
46
Reverse PV Polarity
47
Battery Full
47
Remote Terminal Is Missing, Is Disconnected or External Control Is Active
47
The Charger Is Disabled
47
PV Voltage too Low
48
Battery Voltage Setting too Low
49
Controlled by an External Device
49
Battery Supply Issue
49
PV Voltage too High
50
Batteries Are Undercharged
51
Too Much DC Load
51
Battery Charge Voltages Are too Low
51
The Battery Is Almost Full
51
Battery Cable Voltage Drop
51
Temperature Difference between Solar Charger and Battery
52
Insufficient Solar
52
Wrong Temperature Compensation Setting
53
Battery Charge Current too Low
53
Batteries Are Overcharged
53
Battery Voltage Setting too High
53
Battery Charge Voltages too High
54
Battery Unable to Deal with Equalization
54
Battery Old or Faulty
54
Solar Issues
55
PV Reverse Current too High
55
PV Yield Less than Expected
55
Full Rated Output Not Reached
55
Max PV Output Power Relates to Battery Voltage
56
Mixed PV Panel Types
56
PV Connections Burned or Melted
56
MC4 Connectors Wrongly Connected
57
Optimisers Cannot be Used
57
Earth Fault Detection Missing
57
Ground Current
57
Communication Issues
57
Victronconnect Issues
57
Ve.direct Port Communication Issues
57
Ve.can Port Communication Issues
58
Ve.smart Communication Issues
58
Bluetooth Issues
58
Settings or Firmware Issues
59
Incorrect Settings
59
Firmware Issues
59
Interrupted Firmware Update
60
Operation Issues
60
Unable to Operate as a Power Supply
60
Unable to Operate as a DC to DC Charger
60
Relay Issues
60
10 Technical Specifications
61
Specifications 150/70, 150/85 and 150/100
61
Specifications 250/70, 250/85 and 250/100
63
11 Appendix
65
Dimensions 70A-MC4-Ve.can
65
Dimensions 70A-Tr-Ve.can
66
Dimensions 85A-MC4-Ve.can and 100A-MC4-Ve.can
66
Dimensions 85A-Tr-Ve.can and 100A-Tr-Ve.can
67
Charger Error Code Overview
68
Victron energy MPPT Control Manual (16 pages)
Brand:
Victron energy
| Category:
Monitor
| Size: 1 MB
Table of Contents
Table of Contents
2
1 Introduction
3
2 Mounting
5
3 Installation
7
4 Operation
9
Status Menu
10
History Menu
10
Settings Menu
12
5 Troubleshooting and Support
14
Power Issues
14
Connection Issues
14
Settings Locked
14
6 Warranty
15
7 Specifications
16
Advertisement
Victron energy MPPT Control Manual (4 pages)
Brand:
Victron energy
| Category:
Controller
| Size: 0 MB
Table of Contents
Installation
1
Specifications
1
Buttons and Display
1
Menus
2
Status
2
History
2
History Topics
2
Overall Topics
3
Daily Topics
3
Settings
3
Editing Settings
4
Advertisement
Related Products
Victron energy BlueSolar MPPT 100/15
Victron energy BlueSolar MPPT 100/50
Victron energy BlueSolar MPPT 150/70
Victron energy BlueSolar MPPT 70/15
Victron energy BlueSolar MPPT 75/10
Victron energy BlueSolar MPPT 75/15
Victron energy MPPT 100/20
Victron energy BlueSolar MPPT 150/60
Victron energy BlueSolar MPPT 150/45
Victron energy SmartSolar MPPT 150/85 Series
Victron energy Categories
Inverter
Battery Charger
Controller
Measuring Instruments
Modem
More Victron energy Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL