Operation Of The Product - Bosch Rexroth PS5000 Commissioning And Operating Instructions

Operating and diagnostic terminal
Hide thumbs Also See for Rexroth PS5000:
Table of Contents

Advertisement

1−8
Bosch Rexroth AG
Safety Instructions
1.7

Operation of the Product

Electric Drives
and Controls
DANGER
In the environment of resistance welding systems, magnetic field
strengths have to be expected which are above the limit values
specified in VDE 0848 Part 4. Especially if manual guns are used,
the limit values for extremities may be exceeded.
In cases of doubt, you should measure the field strength and take
additional measures to ensure safety and health at work. Please
comply with regulation BGV B11 of the German Berufsgenossen-
schaft (professional association) "Unfallverhütungsvorschrift
elektromagnetische Felder".
DANGER
The strong magnetic fields occurring in resistance welding may
affect the proper functioning of pacemakers. This may be fatal or
cause serious personal injury!
Therefore, persons with pacemakers must stay clear of resistance
welding systems.
We recommend that warning sings as per DIN 40023 are posted at
every entrance to manufacturing shops housing resistance-wel-
ding equipment:
DANGER
Danger of personal injury and damage to property if devices are
operated before they have been properly installed!
The devices are designed to be installed in housings or switch-
gear cabinets and must not be operated unless properly installed
and switchgear cabinet doors are closed!
No entry for persons with cardiac
pacemakers!
Danger!
BT 6.190
1070087068 / 01

Advertisement

Table of Contents
loading

This manual is also suitable for:

Rexroth ps6000Rexroth bt 6.190

Table of Contents