Quick Mode - Bosch Rexroth PS5000 Commissioning And Operating Instructions

Operating and diagnostic terminal
Hide thumbs Also See for Rexroth PS5000:
Table of Contents

Advertisement

1070087068 / 01
BT 6.190
Operation
4.4

Quick mode

Use the direct selection mode to immediately open a certain screen wit-
hin any sublevel.
Proceed as follows:
L
At any time, you can press
.
the
key to return to the uppermost menu level, or
the
key to return to the previously displayed menu level.
1. Press the
key.
F
The BT 6.190 switches to direct selection mode. This is indicated by
lighting of the integrated key LED.
The screen for selecting a parameter number appears:
1st line: DIRECT MODE
2nd line:Program <No.>
3rd line: Parameter number <No.>
4th line: <Description of the parameter in plain text>
2. If a specificseam program must be selected, use the
to move the cursor into the 2nd line and set the desired number.
To do this, use the numeric keys or keys
3. If you used the numeric keys to make the selection, press
the displayed number.
4. Use the
or
desired parameter number with the numeric keys or keys
The following table provides an overview of the available parameter
numbers.
5. If you used the numeric keys to select the parameter, press
lect the displayed parameter number.
Line 4 shows the associated parameter name in plain text. If a para-
.
meter number that is unavailable or undefined is selected, the BT
6.190 issues the text "not available" in line 4.
6. Press the
key.
F
The BT 6.190 switches to the selected sublevel. The integrated key
LED goes out.