1-13. Settings and Adjustment when External Equipment is Connected

1-13. Settings and Adjustment when External Equipment is Connected

1-13-1. Settings for Time Code

Set the TC GENERATOR switches on the upper control panel as follows.
Case
When editing with an
editor (BVE-2000, etc.)
capable of the 1st edit
When editing with direct
machine-to-machine
(VTR-to-VTR)

1-13-2. VTR Constant Values Settings of Editor

Set the VTR constant values according to the table below when the editor which needs the setting of VTR
constant values is connected. Moreover, the change of VTR constant values are required when the 525/
625 system is switched by setup menu of this unit.
Model name
525/625
1
DNW-A75
525/60
B0
DNW-A75P
625/50
B1
*: Set the data of No.8 of the VTR CONSTANT 1 to "0A" for the following editors.
. BVE-900 ROM versions earlier than 1.08
. BVE-600 ROM versions earlier than 1.01
n
When remote-controlling this unit by the editor, set the setup menu ITEM-401: FUNCTION MODE
AFTER CUE-UP to "STOP".
1-26
TC GENERATOR switch
INT / EXT
PRESET / REGEN
FREE RUN / REC RUN
INT / EXT
PRESET / REGEN
FREE RUN / REC RUN
VTR CONSTANT 1
Data No.
2
3
4
5
6
46
00
96
07
07
46
00
7D
07
07
Setting
Remarks
INT
PRESET
FREE RUN
INT
The setup menu ITEM-610:
REGEN CONTROL MODE
PRESET
must be set to "AS&IN".
REC RUN
VTR CONSTANT 2
Data No.
7
8
1
2
3
4
*
03
8A
0A
07
FB
00
03
8A
*
0A
06
FB
00
5
6
7
8
81
3D
FF
5A
83
4B
FF
4B
DNW-A75/A75P