4-2. TAPE Maintenance Mode (M0)
4-2-10. AUDIO/VIDEO ADJUST Mode (A2)
Note on manual adjustment
Check the adjustment data range in which the SCH status
is set to "1" and set the adjustment data to the intermediate
value in performing the manual adjustment.
n
For the manual adjustment, refer to the "To change the
adjustment data manually" on page 4-67.
Example of display and operation
Superimposed display
AUDIO/VIDEO ADJUST MODE
A24:INPUT CF DETECT
*
Manual
INPUT CF DETECT
9E
SCH
0
SFTZ
0
SFTP
0
[JOG] + DIAL (2)
(1) 0
AUDIO/VIDEO ADJUST MODE
A24:INPUT CF DETECT
*
Auto (Push SET button)
INPUT CF DETECT
9E
SCH
0
SFTZ
0
SFTP
0
(2) 0 [SET]
AUDIO/VIDEO ADJUST MODE
A24:INPUT CF DETECT
*
Auto Adjusting ...
INPUT CF DETECT
00
SCH
0
SFTZ
0
SFTP
0
0
(omitted)
0
AUDIO/VIDEO ADJUST MODE
A24:INPUT CF DETECT
*
Auto Adjust Complete
INPUT CF DETECT
85
SCH
1
SFTZ
1
SFTP
1
0
(3)
0
Check
[MENU]
(4)
0
[MENU]
(5)
0
0
Data save
* A2F:NV-RAM CONTROL
4-72
Time data display area
MANUAL
PUSH SET
PUSH SET
PUSH SET
DNW-A75/A75P