Sony DNW-A75 Maintenance Manual page 131

Hide thumbs Also See for DNW-A75:
Table of Contents

Advertisement

SOMETHING CHECK
Screen display
15. ECC ENC CHECK. NG
MACRO SEQ ERR
EXT FIFO FULL WARN
PACK2 NOT FIN ERR
SDRAM ERR
EXT FIFO ERR B
EXT FIFO ERR A
PARITY ERR SX-IN
PARITY ERR AUD-0
PARITY ERR AUD-1
16. OUTER CHECK. NG
PARITY ERR xx
n
On "xx displays the number of the input parity errors.
SDRAM ERR NT
SDRAM ERR JOG
17. SX DEC CHECK. NG
SDRAM ERR ALL
n
Displays "ALL" wherever an abnormal point occurs.
PARITY ERR MEP
PARITY ERR STREAM
CLOCK ERR 13.5M
CLOCK ERR 27M
CLOCK ERR 54M
CLOCK ERR 81M
DNW-A75/A75P
Target IC (Its pin number)
[Ref. No. of Connected IC]
IC402 (Data is abnormal)
IC402, [IC403]
IC402, [IC401]
IC402, [IC400]
IC402 (Pins 60 to 69), [IC200]
IC402 (Pin 140)
IC402 (Pin 141)
IC600
(Pins 49, 50, 57 to 59, 62 to 66)
IC600, [IC603]
IC600, [IC601, IC602]
IC800, [IC801, IC802]
IC800
(Internal connection of IC800)
IC800 (Pins 88 to 95, 98, 112)
IC800
(Pins 99, 120 to 124, 127 to 132)
C25 : DPR-119 DIAG INFO
AUDIO/VIDEO CHECK MODE
C25:DPR-119 DIAG INFO
DPR-119 DIAG. OK!
This function informs the result of the self-diagnosis of the
DPR-119 board of BKNW-118. It is displayed when the
BKNW-118 option is installed.
When a failure occurs on the DPR-119 board, this function
guess the default IC but do not specified.
n
"ERROR" may be displayed as the diagnosis result even if
the boards except DPR-119 are defective.
An initialize check and something check are available as
the self-diagnosis function.
. In the initialize check, check the communication of the
communication bus (PAD0-7, STAT0-1, STRB, and CS)
between SY2 CPU on the SS-83 board and IC213 or
IC216 on the DPR-119 board.
Initialization data is transferred from SY2 CPU to each IC.
After that, the initialization data set in each IC is read and
compared with the initialization data transferred at first.
. In the something check, a parity check and FIFO memo-
ry check are performed for the input signals of IC200,
and the result of the self-diagnosis of IC200 is displayed
by reading from SY2 CPU on the SS-83 board.
Target IC for the diagnosis
Screen
Target IC
No. display
Ref. No. (IC name)
1
SDTI TX
IC213 (CXD8969AR)
2
AU FEED IC106 (CXD211-124Q)
13
V-PACK
IC200 (CXD8977R)
To display the self-diagnosis function result
(1) Select the C25 : DPR-119 DIAG INFO menu.
(2) To scroll the screen, turn the JOG dial.
Downward: Turn it in REVERSE (3) direction.
Upward:
Turn it in FORWARD (2) direction.
(3) Press the MENU button to terminate the menu after
checking the self-diagnosis result.
4-2. TAPE Maintenance Mode (M0)
4-2-5. AUDIO/VIDEO CHECK Mode (C2)
Remarks
Initialize check only
Initialize check only
Something check only
4-41

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Dnw-a75p1000140001

Table of Contents