1-10. Switch and Shorting Plug Settings on PC Boards
Monitor output level settings
Channel
Ref. No.
L
COR902
R
COR952
Monitor output headroom settings
Channel
Ref. No.
L
COR900
R
COR950
Monitor output level switching (fixed or variable)
When the variable level is selected, the level is adjusted with the PHONE level control knob.
Channel
Ref. No.
L
COR901
R
COR951
1-18
Display
Output level (dBm/600 Z) [ ]: Factory setting
[+4]
0
Short
Open
+4
0
Open
Short
_3
Open
Open
_20
Open
Open
+4
Short
Open
0
Open
Short
_3
Open
Open
_20
Open
Open
Display
Output headroom (dB) [ ]: Factory setting
[20]
18
20
Short
Open
18
Open
Short
16
Open
Open
20
Short
Open
18
Open
Short
16
Open
Open
Display
Monitor output level
[Fixed]
Variable
UNITY(L)
Short
Open
VAR(L)
Open
Short
UNITY(R)
Short
Open
VAR(R)
Open
Short
Fine adjustment
_3
_20
Open
Open
RV900
Open
Open
Short
Open
Open
Short
Open
Open
RV1000
Open
Open
Short
Open
Open
Short
Fine adjustment
16
Open
RV900
Open
Short
Open
RV1000
Open
Short
[ ]: Factory setting