Page 1
> > Operating Instructions IO-Link Master with AS-Interface Interface StandardLine 2 Ports IP 65 / IP 66 / IP 67 AC6002 Firmware: 2.4.x or higher English...
Page 2
Device structure ......................... 20 9.1.2 Options for parameter setting ..................... 20 9.1.3 Using the command interface ..................... 21 Addressing the AS-i slave of the AC6002 ................23 9.2.1 Addressing via AS-i master ......................23 9.2.2 Addressing with addressing unit ....................24...
Page 3
IO-Link Master with AS-Interface Interface StandardLine 2 Ports IP 65 / IP 66 / IP 67 Adjusting the gateway profile .....................25 9.3.1 Example: Adjusting the gateway profile ..................25 Configuring IO-Link ports ....................26 9.4.1 Note: Device validation and data storage ................... 26 Reading / writing parameters of the IO-Link devices ............27 9.5.1 Example: Reading parameter .....................
Page 5
IO-Link Master with AS-Interface Interface StandardLine 2 Ports IP 65 / IP 66 / IP 67 > Symbols used 58277 Important note Non-compliance can result in malfunction or interference Information Supplementary note ► ... Request for action > Reaction, result →...
Page 6
Parameter setting and command interface Maintenance, repair, disposal Programming manual Parameter setting with CODESYS function library ifm provides the documents for download on its website: → www.ifm.com > Modification history 34492 Version Topic Date New creation of document...
Page 7
IO-Link Master with AS-Interface Interface StandardLine 2 Ports IP 65 / IP 66 / IP 67 Safety instructions Content General ..............................7 28333 > General 59299 The device described is a subcomponent for integration into a system. The system architect is •...
Page 8
IO-Link Master with AS-Interface Interface StandardLine 2 Ports IP 65 / IP 66 / IP 67 Functions and features 59300 The device may only be used for the following purposes: as IO-Link master to configure and control the connected IO-Link devices •...
Page 9
IO-Link Master with AS-Interface Interface StandardLine 2 Ports IP 65 / IP 66 / IP 67 Function Content IO-Link ..............................10 AS-interface ............................10 Parameter setting ...........................10 Visual indication ............................10 33836...
Page 10
IO-Link Master with AS-Interface Interface StandardLine 2 Ports IP 65 / IP 66 / IP 67 > IO-Link 59322 The device offers the following IO-Link functions: IO-Link master (IO-Link revision 1.0 and 1.1) • 2 IO-Link ports to connect IO-Link devices •...
Page 11
IO-Link Master with AS-Interface Interface StandardLine 2 Ports IP 65 / IP 66 / IP 67 Mounting Content Mounting the device ..........................11 34058 > Mounting the device 34059 ► Disconnect the system from power before installation. ► For installation choose a flat mounting surface. ►...
Page 12
IO-Link Master with AS-Interface Interface StandardLine 2 Ports IP 65 / IP 66 / IP 67 Electrical connection Content Notes ..............................12 IO-Link ports ............................13 Connecting the unit ..........................15 33805 > Notes 51957 A qualified electrician must connect the unit. ► The national and international for regulations setting up electrical equipment must be complied with.
Page 13
> IO-Link ports 51958 The IO-Link ports of the AC6002 meet the requirements of the IO-Link specifications 1.0 to 1.1.2. ► Please note the information concerning IO-Link wiring! ► Cover unused sockets with M12 protective caps (art. no.: E73004). Tightening torque 0.6...0.8 Nm ...
Page 14
IO-Link Master with AS-Interface Interface StandardLine 2 Ports IP 65 / IP 66 / IP 67 > 6.2.2 Connecting IO-Link devices for Class B operation 51960 Notes on wiring: • For Class B operation, the IO-Link device must be supplied with an additional auxiliary voltage UA using a Y connection cable.
Page 15
► Connect the device to the AUX supply voltage via the M12 socket X21 (24 V DC (20...300 V SELV/PELV)). ► Connect an additional AS-i device to the M12 socket X22 of the AC6002 (loop-through function). Tightening torque: 0.6...0.8 Nm Recommended maximum cable length: 25 m ...
Page 16
IO-Link Master with AS-Interface Interface StandardLine 2 Ports IP 65 / IP 66 / IP 67 Operating and display elements Content Overview ..............................16 LED indicators ............................17 34063 > Overview 58531 Status LEDs RDY and FLT (→ Status LEDs (→ p. 17)) IOL and DI status LEDs of the IO-Link port (X01...X02 (→...
Page 17
IO-Link Master with AS-Interface Interface StandardLine 2 Ports IP 65 / IP 66 / IP 67 > LED indicators 34047 The device only has the following LED indicators: > 7.2.1 Status LEDs 51964 The RDY LED indicates the status of the gateway. The FLT LED shows the status of the AS-Interfaceconnection.
Page 18
IO-Link Master with AS-Interface Interface StandardLine 2 Ports IP 65 / IP 66 / IP 67 Set-up 59304 When the supply voltage has been switched on, the AC6002 starts with the factory settings. The display elements signal the current operating status (→ Operating and display elements (→...
IO-Link Master with AS-Interface Interface StandardLine 2 Ports IP 65 / IP 66 / IP 67 Configuration Content Notes ..............................20 Addressing the AS-i slave of the AC6002 ....................23 Adjusting the gateway profile........................25 Configuring IO-Link ports ........................26 Reading / writing parameters of the IO-Link devices ................27 Reading / writing process data .......................32...
Setting the gateway profile (= setting the ID1 code of the basic AS-i slave) • To set the parameters of the IO-Link master and the IO-Link ports of the AC6002 and the connected IO-Link devices, the access to process and diagnostic data as well as maintenance functions, the following options are available: Command interface (→...
Page 21
Principle of the command processing 51973 The basic AS-i slave of the AC6002 has the CTT1 profile S-7.4. It supports the AS-i command interface. The user can use the following AS-i commands to access the IO-Link master using acyclic IO-Link commands: Write Parameter String (S-7.4): Send IO-Link command request...
Page 22
IO-Link Master with AS-Interface Interface StandardLine 2 Ports IP 65 / IP 66 / IP 67 > Procedure: Sending acyclic command to the IO-Link master 51974 The following figure shows the chronological sequence of an acyclic IO-Link command by means of the AS-i commands: Write Parameter String S-7.4...
• AS-Interface addressing unit AC1154: → (→ p. 24) Depending on the set ID1 code, the AC6002 takes up a space of up to 5 connected AS-i Adjusting the gateway profile addresses in the AS-i network. (→ (→ p. 25)).
Page 24
► Connect the addressed AC6002 with the AS-i network. > AS-i master shows configuration error. ► Re-configure the AS-i network. > AC6002 has a valid AS-i address. > AS-i master switches to operating mode "Protected mode". > Cyclic process data is transferred between the AS-i master and AC6002.
(→ p. 43)). In the factory settings, the AC6002 is a single AS-i slave. It has the CTT1 profile S-7.4.E (ID1 = 0xF) with 4 analogue input channels. In each channel, 2 bytes of input data of an IO-Link port are transmitted (mapping: →...
IO-Link Master with AS-Interface Interface StandardLine 2 Ports IP 65 / IP 66 / IP 67 > Configuring IO-Link ports 59311 The configuration of an IO-Link port consists of the following parameters: Operating mode (IO-Link, digital input, digital output, disabled) •...
→ Operating instructions of the IO-Link device Requirements: IO-Link port is in the operating mode "IO-Link". • IO-Link device is connected to the IO-Link port of the AC6002. • Available commands: Name Description...
Page 28
The parameter of the IO-Link device at IO-Link port X02 is to be read (AS-i master: 1, AS-i slave address: 2, Index: 15000, sub-index: 0; parameter length: 172 bytes) Solution: Send read command with "Write Parameter String (S-7.4) to AC6002; read the parameter value that has been read with 2x "Read Parameter String (S-7.4). Course: Write Parameter String S-7.4...
Page 29
IO-Link Master with AS-Interface Interface StandardLine 2 Ports IP 65 / IP 66 / IP 67 > Data range of the command response contains "Read Parameter" command response (first segment): Parameter Value Note Block Counter 0x00...0xFF cons. number Block-ID 0x01 first segment;...
Page 30
Parameter of the IO-Link devices on IO-Link port X02 is to be written (AS-i master: 1, AS-i slave address: 2, Index: 15000, sub-index: 0; parameter length: 192 bytes) Solution: Send parameter value with 2x "Write Parameter String (S-7.4)" to AC6002; verify the success of each write operation with "Read Parameter String (S-7.4)" Course: Write Parameter String S-7.4...
Page 31
IO-Link Master with AS-Interface Interface StandardLine 2 Ports IP 65 / IP 66 / IP 67 ► Data range of the command request: → step 1 (bytes 0...6) > Data range of the command response contains "Read Parameter" command response Parameter Value Note...
Reading / writing process data 59314 In the "Protected mode", the AC6002 provides the cyclic process data of the IO-Link ports via the gateway function in the AS-i network. Additionally, the user can access the process data of the inputs and outputs acyclically.
► After the firmware update: Restart AC6002. Available commands: Name Description Reference 0x0D: Update Firmware Update the firmware of the IO-Link master 0x0D: Update Firmware (→ p. 89) ifm recommends using the function block "_FWUpdate" of the library ifm_AC600x_Lib for CODESYS for the firmware update.
Page 34
► Save changes. Replace IO-Link device ► Disconnect old IO-Link device from IO-Link master. ► Connect new IO-Link device with the same IO-Link port of the AC6002. > IO-Link master copies parameter values from the data memory to the new IO-Link device.
Page 35
IO-Link Master with AS-Interface Interface StandardLine 2 Ports IP 65 / IP 66 / IP 67 Factory settings 51993 In the factory settings, the device has the following parameter settings: Parameter Value Data memory (Data Storage) empty AS-i slave address CTT1 profile S-7.4.E (ID1 = 0xF)
Page 36
IO-Link Master with AS-Interface Interface StandardLine 2 Ports IP 65 / IP 66 / IP 67 Accessories 33870 List of accessories of AC6002: → www.ifm.com > Product page > Accessories...
Page 37
IO-Link Master with AS-Interface Interface StandardLine 2 Ports IP 65 / IP 66 / IP 67 Appendix Content Technical data ............................38 AS-Interface ............................42 Command interface ..........................60 33879...
IO-Link Master with AS-Interface Interface StandardLine 2 Ports IP 65 / IP 66 / IP 67 > 13.1.4 Inputs 59332 Inputs Number of digital inputs 4; (IO-Link Ports Class A: 2 x 2) Sensor supply AS-i Switching level high [V] 11...30 Switching level low [V] 0...5...
IO-Link Master with AS-Interface Interface StandardLine 2 Ports IP 65 / IP 66 / IP 67 > 13.1.8 Approvals / Tests 52813 Approvals / Tests EN 61000-6-2 EN 61000-6-4 Shock resistance DIN EN 60068-2-27 Vibration resistance DIN EN 60068-2-64 2009-04 ...
IO-Link Master with AS-Interface Interface StandardLine 2 Ports IP 65 / IP 66 / IP 67 > 13.1.11 Electrical connection 58493 AS-i IN X21 Connector Wiring AS-i + AUX - bridged AS-i - AUX + bridged AS-i OUT X22 Connector Wiring AS-i + AUX - bridged...
Page 42
IO-Link Master with AS-Interface Interface StandardLine 2 Ports IP 65 / IP 66 / IP 67 > 13.2 AS-Interface Content Mapping: inputs and outputs of the IO-Link ports ..................43 52002...
Page 43
IO-Link Master with AS-Interface Interface StandardLine 2 Ports IP 65 / IP 66 / IP 67 > 13.2.1 Mapping: inputs and outputs of the IO-Link ports Content ID1 = 0x1 ..............................44 ID1 = 0x2 ..............................45 ID1 = 0x4 ..............................46 ID1 = 0x5 ..............................47 ID1 = 0x6 ..............................48 ID1 = 0x7 ..............................49 ID1 = 0x8 ..............................50...
IO-Link Master with AS-Interface Interface StandardLine 2 Ports IP 65 / IP 66 / IP 67 > ID1 = 0x1 59335 Add. Slave (n+1) Basic Slave (n) S-7.3.E, ID1=1 S-7.4.E Port X01 Mapping: Status information Port X02 (→ p. 58) Legend: = 1...30 (valid address range of the Basic AS-i slave) = Word x of the process data at the input of the IO-Link port...
IO-Link Master with AS-Interface Interface StandardLine 2 Ports IP 65 / IP 66 / IP 67 > ID1 = 0xB 59344 Add. Slave (n+1) Basic Slave (n) S-7.3.2, ID1=1 S.-7.4.E Port X01 Mapping: Status information Port X02 (→ p. 58) Legend: = 1...30 (valid address range of the Basic AS-i slave) = Word y of the process data at the output of the IO-Link port...
IO-Link Master with AS-Interface Interface StandardLine 2 Ports IP 65 / IP 66 / IP 67 > ID1 = 0xD 59346 Add. Slave (n+1) Basic Slave (n) S-7.3.E, ID1=1 S-7.4.E Port X01 Mapping: Status information Port X02 (→ p. 58) Legend: = 1...30 (valid address range of the Basic AS-i slave) = Word x of the process data at the input of the IO-Link port...
IO-Link Master with AS-Interface Interface StandardLine 2 Ports IP 65 / IP 66 / IP 67 > ID1 = 0xE 59347 Basic Slave (n) S-7.4.E Port X01 Port X02 Legend: = 1...31 (valid address range of the Basic AS-i slave) = Word x of the process data at the input of the IO-Link port...
IO-Link Master with AS-Interface Interface StandardLine 2 Ports IP 65 / IP 66 / IP 67 > ID1 = 0xF 59348 Basic Slave (n) S-7.4.E Port X01 Port X02 Legend: = 1...31 (valid address range of the Basic AS-i slave) = Word x of the process data at the input of the IO-Link port...
IO-Link Master with AS-Interface Interface StandardLine 2 Ports IP 65 / IP 66 / IP 67 > Mapping: Status information 59349 Basic slave channel reserved X01/ Port X01: PQI reserved res. Resp reserved Port X02: PQI Number of Events in Buffer reserved Legend: Short Circuit: indicates whether there is a short circuit on at least...
IO-Link Master with AS-Interface Interface StandardLine 2 Ports IP 65 / IP 66 / IP 67 > Mapping: PQI 52019 DACT res. res. DI (Pin 2) DI (Pin 4) Legend: DI (Pin 4) Signal level of the digital input on pin 4 (if in use) 1 bit ...
IO-Link Master with AS-Interface Interface StandardLine 2 Ports IP 65 / IP 66 / IP 67 > 13.3 Command interface Content Structure of the command interface .......................60 Overview: Acyclic commands .........................63 0x01: Read IO-Link Port Configuration Errors..................64 0x02: Write IO-Link Port Configuration ....................65 0x03: Read IO-Link Port Configuration ....................69 0x04: Read Input Process Data ......................72 0x05: Read Output Process Data ......................74...
Page 61
IO-Link Master with AS-Interface Interface StandardLine 2 Ports IP 65 / IP 66 / IP 67 > Command request (AS-i master >>> IO-Link master) 59351 Byte Contents Block ID Command ID Target ID Request Data Length 4...160 Request Data Legend: [Block ID] Fragmentation information for data transfer via 1 byte...
Page 62
IO-Link Master with AS-Interface Interface StandardLine 2 Ports IP 65 / IP 66 / IP 67 > Command response (IO-Link master >>> AS-i master) 52120 Byte Contents Block ID Block Counter Command Status Response Data Length 4...160 Response Data Legend: [Block ID] Fragmentation information for data transfer via 8 bits...
IO-Link Master with AS-Interface Interface StandardLine 2 Ports IP 65 / IP 66 / IP 67 > 13.3.3 0x01: Read IO-Link Port Configuration Errors 52123 The command verifies whether the projected parameters "Vendor ID" and "Device ID" correspond with the parameter values of the connected IO-Link devices at the IO-Link ports X01...X02. >...
IO-Link Master with AS-Interface Interface StandardLine 2 Ports IP 65 / IP 66 / IP 67 > 13.3.4 0x02: Write IO-Link Port Configuration 52127 The command writes the configuration of the IO-Link ports X01...X02 of the IO-Link master. The configuration consists of the following parameters: •...
Page 66
IO-Link Master with AS-Interface Interface StandardLine 2 Ports IP 65 / IP 66 / IP 67 > Command request 59353 Byte 0x00 0x02 0x0A 0x28 Port X01: Port Mode Port X01: Master Cycle Time Port X01: Validation ID Port X01: Vendor ID (MSB) Port X01: Vendor ID (LSB) Port X01: Device ID (MSB) Port X01: Device ID...
Page 67
IO-Link Master with AS-Interface Interface StandardLine 2 Ports IP 65 / IP 66 / IP 67 [Vendor ID] Vendor ID of the manufacturer of the device 2 bytes per byte: 0x00...0xFF on the IO-Link port Vendor ID = 0x1234 Vendor ID (MSB) = 0x12 ...
Page 68
IO-Link Master with AS-Interface Interface StandardLine 2 Ports IP 65 / IP 66 / IP 67 > Command response 52129 Byte 0x00 Block Counter Command status (→ list "Diagnostic codes") 0x00 4...160 ignored Diagnostic codes: 0x01 0x04 Blocked Port - another acyclic access is still active ...
IO-Link Master with AS-Interface Interface StandardLine 2 Ports IP 65 / IP 66 / IP 67 > 13.3.5 0x03: Read IO-Link Port Configuration 52130 The command reads the current configuration of the IO-Link ports X01...X02 of the IO-Link master. The configuration consists of the following parameters: •...
Page 70
IO-Link Master with AS-Interface Interface StandardLine 2 Ports IP 65 / IP 66 / IP 67 > Command response 59354 Byte 0x00 Block Counter Command status (→ list "Diagnostic codes") 0x28 Port X01: Port Mode Port X01: Master Cycle Time Port X01: Validation ID Port X01: Vendor ID (MSB) Port X01: Vendor ID (LSB)
Page 71
IO-Link Master with AS-Interface Interface StandardLine 2 Ports IP 65 / IP 66 / IP 67 [Vendor ID] Vendor ID of the manufacturer of the device 2 bytes per byte: 0x00...0xFF on the IO-Link port Vendor ID = 0x1234 Vendor ID (MSB) = 0x12 ...
IO-Link Master with AS-Interface Interface StandardLine 2 Ports IP 65 / IP 66 / IP 67 > 13.3.6 0x04: Read Input Process Data 52133 The command reads the process data of the inputs of an IO-Link port of the IO-Link master and the corresponding status information (PQI).
Page 73
IO-Link Master with AS-Interface Interface StandardLine 2 Ports IP 65 / IP 66 / IP 67 > Command response 52135 Byte 0x00 Block Counter Command status (→ list "Diagnostic codes") Response Data Length DACT res. res. DI (Pin2) DI (Pin 4) Input data (byte 1) 5+(n-1) Input data (byte n)
IO-Link Master with AS-Interface Interface StandardLine 2 Ports IP 65 / IP 66 / IP 67 > 13.3.7 0x05: Read Output Process Data 52136 The command reads the process data of the outputs of an IO-Link port of the IO-Link master. >...
Page 75
IO-Link Master with AS-Interface Interface StandardLine 2 Ports IP 65 / IP 66 / IP 67 > Command response 52138 Byte 0x00 Block Counter Command status (→ list "Diagnostic codes") Response data length (number of bytes m) Output acyclic process data switch (OPDS) Output Data (Byte 1) 5+(n-1) Output Data (Byte n)
IO-Link Master with AS-Interface Interface StandardLine 2 Ports IP 65 / IP 66 / IP 67 > 13.3.8 0x06: Write Output Process Data 52139 The command writes the process data of the outputs of an IO-Link port of the IO-Link master. If the flag [OPDS] is set to 0x01, then the cyclic output of process data is blocked.
Page 77
IO-Link Master with AS-Interface Interface StandardLine 2 Ports IP 65 / IP 66 / IP 67 > Command response 52141 Byte 0x00 Block Counter Command status (→ list "Diagnostic codes") 0x00 4...160 ignored Diagnostic codes: 0x01 0x04 Blocked Port - another acyclic access is still active ...
IO-Link Master with AS-Interface Interface StandardLine 2 Ports IP 65 / IP 66 / IP 67 > 13.3.9 0x07: Read Diagnosis Data 52142 The command reads the diagnostic information / events) of the IO-Link devices. The diagnostic information is stored in a ring buffer in the IO-Link master. The ring buffer stores a maximum of 12 events.
Page 79
IO-Link Master with AS-Interface Interface StandardLine 2 Ports IP 65 / IP 66 / IP 67 > Command response 59358 Byte 0x00 Block Counter Command status (→ list "Diagnostic codes") 0x05 IO-Link Port Mode Type Event Code (MSB) Event Code (LSB) 9...160 ignored Legend:...
IO-Link Master with AS-Interface Interface StandardLine 2 Ports IP 65 / IP 66 / IP 67 > 13.3.10 0x08: Factory Defaults 52145 The command resets the configuration of the IO-Link ports of the IO-Link master to the factory settings. The bytes 4...8 contain the "reset" string in hexadecimal representation. >...
IO-Link Master with AS-Interface Interface StandardLine 2 Ports IP 65 / IP 66 / IP 67 > 13.3.11 0x09: Set IO-Link Failsafe Data 52148 The command writes the fail-safe value of the output of an IO-Link port of the IO-Link master ("IO-Link"...
IO-Link Master with AS-Interface Interface StandardLine 2 Ports IP 65 / IP 66 / IP 67 > 13.3.12 0x0A: Write Parameter 52151 The command writes the parameter on an IO-Link device connected to the IO-Link master. Parameters with a length <= 150 bytes are transferred with an acyclic write command (block ID = 0x00).
Page 83
IO-Link Master with AS-Interface Interface StandardLine 2 Ports IP 65 / IP 66 / IP 67 > Command request 59360 Byte Block ID 0x0A Target ID Data Length Index (LSB) Index (MSB) Sub-index Parameter Data Length (n Bytes) Parameter Data (Byte 1) 8+(n-1) Parameter Data (Byte n) (8+n)...160...
Page 84
IO-Link Master with AS-Interface Interface StandardLine 2 Ports IP 65 / IP 66 / IP 67 > Command response 52153 Byte 0x00 Block Counter Command status (→ list "Diagnostic codes") Data Length ignored / Error Code ignored / Additional Error Code 6...160 ignored Legend:...
IO-Link Master with AS-Interface Interface StandardLine 2 Ports IP 65 / IP 66 / IP 67 > 13.3.13 0x0B: Read Parameter 52154 The command reads the parameter of an IO-Link device connected to the IO-Link master. The parameter can be accessed via index and sub-index of the corresponding IO-Link object. Parameters that are longer than 150 bytes are read with 2 acyclic commands.
Page 86
IO-Link Master with AS-Interface Interface StandardLine 2 Ports IP 65 / IP 66 / IP 67 > Command response 52156 Byte Block-ID Block Counter Command status (→ list "Diagnostic codes") Parameter Data Length (n Bytes) Parameter Data (Byte 1) 4+(n-1) Parameter Data (Byte n) (4+n)...160 ignored...
IO-Link Master with AS-Interface Interface StandardLine 2 Ports IP 65 / IP 66 / IP 67 > 13.3.14 0x0C: Read Device Name, Serial Number, HW and SW Revisions 52157 The command reads the following parameters of the IO-Link master: • Device Name Serial number •...
Page 88
IO-Link Master with AS-Interface Interface StandardLine 2 Ports IP 65 / IP 66 / IP 67 > Command response 52159 Byte 0x00 Block Counter Command status (→ list "Diagnostic codes") 0x32 0...5 Device Name 0x20 7...18 Serial Number 0x20 20...21 Hardware revision 0x20 23...35...
The command uses 1 AS-i input slave and 4 AS-i output slaves for the data transmission. The valid address range for the basic AS-i slave of the AC6002 is restricted to 1...27. ► Ensure that 5 connected AS-i addresses are available for the update process.
Page 90
File Size (MSB) 12...160 ignored Legend: [File Size] Size of the ifm firmware file in bytes divided by 4 (rounded up value) 16 bits per byte: 0x00...0xFF The IO-Link master calculates the start address in the flash memory from this valuer...
Page 91
IO-Link Master with AS-Interface Interface StandardLine 2 Ports IP 65 / IP 66 / IP 67 > Command response 52162 Byte 0x00 Block Counter Command status (→ list "Diagnostic codes") 0x00 4...160 ignored Diagnostic codes: 0x04 Blocked Port - another acyclic access is still active ...
Page 92
ID1 = 0xD ....................55 ID1 = 0xE ....................56 Accessories ................... 36 ID1 = 0xF ....................57 Addressing the AS-i slave of the AC6002 ..........23 Inputs ..................... 39 Addressing via AS-i master ..............23 Inputs / outputs ..................38 Addressing with addressing unit ............
Page 93
IO-Link Master with AS-Interface Interface StandardLine 2 Ports IP 65 / IP 66 / IP 67 Operating and display elements ............16 Operating conditions ................39 Options for parameter setting ..............20 Outputs ....................39 Overview ....................16 Acyclic commands..................63 Parameter setting ..................