Canon LASER CLASS 730i Service Manual page 135

Hide thumbs Also See for LASER CLASS 730i:
Table of Contents

Advertisement

LASER CLASS 730i/720i/710 Chapter 4: Maintenance and Service
#3 NUMERIC Param.
(Numeric parameter settings)
Default
001:
0
002:
10 (10%)
003:
15 (15 times)
004:
12 (12 lines)
005:
4 (sec)
006:
4 (sec)
007:
0
008:
0
009:
6 (6 digits)
010:
5500 (55 sec)
011:
3500 (35 sec)
012:
0 (0 line)
013:
1300 (13 sec)
014:
0
015:
120 (100 ms)
016:
4
017:
100
018:
0
019:
200
020:
100
021:
0
022:
200
023:
4
024:
20
025:
60
026:
4
027:
0
028:
3 (3 sec)
Item 029 to 055:
055:
No. 001, 007, 008, 012, 014, 029 to 055 and 071 to 080 are not used. Do not
change their settings
Range
Not used
(1~99)
RTN signal transmission condition (1)
(2~99)
RTN signal transmission condition (2)
(1~99)
RTN signal transmission condition (3)
(1~60)
Pause time for NCC (before the ID code)
(1~60)
Pause time for NCC (after the ID code)
Not used
Not used
(1~20)
The number of digits in telephone
compared against TSI signal to be matched
for restricted receiving function
(0~9999)
T0 timer
(0~9999)
T1 timer (Rx)
(0~65535)
Not used
(500~9999)
Maximum time allowed to receive one line
of image data
Not used
(0~999)
Hooking detection time
Not used
Not used
Not used
Not used
Not used
Not used
Not used
Not used
Not used
Not used
Not used
Not used
(1~60)
Menu pop-up time
Not used
Figure 4-17 Service Data 3