Figure 9. Shelf Status Summary Screen; Figure 10. Status Summary Screen - ADTRAN E220 HFAC HDSL Installation And Maintenance Manual

Hdsl / hdsl2 fuse alarm control unit
Hide thumbs Also See for E220 HFAC HDSL:
Table of Contents

Advertisement

Shelf Status Summary Screen
The Shelf Status Summary Screen shown in Figure 9
provides a top-level look at the alarm and
provisioning of data for the shelf and each circuit
within the shelf.
HDSL / HDSL2 Status Screen
From the Shelf Status Summary Screen, detailed
information related to a particular circuit may be
accessed. The HDSL / HDSL2 Shelf Status Summary
08/08/70
17:59:19
ACTIVE SHELF ALARMS
—————————
CRITICAL - YES
MAJOR
- NO
MINOR
- NO
FUSE ALARM SETTINGS
——————————————————
HFAC
: CRIT
HTU-C : 1-5
= MAJ,
6-13 = CRIT
LEGEND
——————————————————
NA
= NOT ALARMED
*
= DEFAULT
= EMPTY SLOT
PRESS :
"O" - change options,
nn"S" - slot select
08/08/70
18:00:37
LOOP #1 <NETWORK> LOOP #2
--------- HTU-C ---------
01 dB
YES
000/00001
000/00000
000/00026
LOOPBACKS INACTIVE
HTU-C SIGNAL QUALITY
[X]
9
[X]
L[X]
8
L[X]
O[X]
7
O[X]
O[X]
6
O[X]
P[X]
5
P[X]
[X]
4
[X]
1[X]
3
2[X]
[X]
2
[X]
[X]
1
[X]
[X]
0
[X]
"P" - prev scrn,
"M" - main menu,
10
SHELF STATUS SUMMARY
HFAC ALARM THRESHOLD OPTION SETTINGS
——————————————————————————————————————————————————————
ES
SLOT
TYPE
THRSHLD
----
-------------
1:
---
2:
---
3:
---
4:
---
5:
---
6:
---
7:* MAJ
8:
---
9:
---
10:
---
11:
---
12:* MAJ
13:* MAJ
"D"
(HDSL STATUS),

Figure 9. Shelf Status Summary Screen

SUMMARY - [ SLOT 7
ELAPSED TIME 00:09:56
01 dB
<-
LOSS
YES
<-
SYNC
000/00001
<- ES
000/00000
<- SES
000/00025
<- UAS
DSX-1
———————————————
SF
<-
FRAME ->
AMI
<-
CODE
EXT
<-
LBO
N/A
<-
NIU
00000
<-
BPV
00000
<-
ES
00000
<-
SES
00324
<-
UAS
RED
<- ALARMS ->
SEALING CURRENT PRESENT
"Z" - clr current reg,

Figure 10. Status Summary Screen

61221051L1-5, Issue 1
screen related to a particular slot may be displayed by
typing the desired slot number and S. For example, to
access Slot 6 information, type 6S. The HDSL /
HDSL2 Status Summary Screen is shown in Figure
10. This screen gives both local and remote
performance and provisioning information for the
selected slot. If a supported HRE is present in the
HDSL / HDSL2 circuit, screen 10A is available to
view the performance of the HRE.
[ BYPASS = OFF ]
SES
TYPE
THRSHLD
-------------
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
---
150
MAJ
075
---
---
---
---
---
---
---
---
---
---
---
---
150
MAJ
075
150
MAJ
075
- read HFAC switch defaults (all slots),
"M"
- main menu :
]
LOOP #1 <CUSTOMER>LOOP #2
--------- HTU-R ---------
->
01 dB
->
YES
15M/24H ->
000/00001
15M/24H ->
000/00000
15M/24H ->
000/00026
LOOPBACKS INACTIVE
DS1
HTU-R SIGNAL QUALITY
[X]
9
[X]
SF
->
AMI
->
0 dB
->
NO
->
00000
->
00000
->
00000
->
00302
RED
nn"S" - slot:
SHELF ADDRESS = 00
UAS
TYPE
THRSHLD
-------------
---
---
---
---
---
---
---
---
---
---
---
---
CRIT
075
---
---
---
---
---
---
---
---
CRIT
075
CRIT
075
SHELF ADDRESS = 00
01 dB
YES
000/00001
000/00001
000/00025
L[X]
8
L[X]
O[X]
7
O[X]
O[X]
6
O[X]
P[X]
5
P[X]
[X]
4
[X]
1[X]
3
2[X]
[X]
2
[X]
[X]
1
[X]
[X]
0
[X]
61221051L1-5A

Advertisement

Table of Contents
loading

This manual is also suitable for:

E220 hfac hdsl2

Table of Contents