ADTRAN Year 2000 (Y2K) Readiness Disclosure ADTRAN has established a Year 2000 program to ensure that our products will correctly function in the new millennium. ADTRAN warrants that all products meet Year 2000 specifications regardless of model or revision. Information about ADTRAN's Year 2000 compliance program is available at the fol-...
Page 4
Part 68-compliant. See Chapter 2, Installation, for details. If your telephone equipment (Quad T1/PRI Module) causes harm to the telephone network, the telephone company may discontinue your service temporarily. If possible, they will notify you in advance.
Page 5
Affidavit Requirements for Connection to Digital Services • An affidavit is required to be given to the telephone company whenever digital terminal equipment without encoded analog content and billing protection is used to transmit digital signals containing encoded analog content which are intended for eventual conversion into voiceband analog signals and transmitted on the network.
Page 6
( ) C. An independent training course (e.g., trade school or technical institution) recognized by the manufacturer/grantee of the equipment used to encode analog signals; or ( ) D. In lieu of the preceding training requirements, the operator(s)/maintainer(s) is (are) under the control of a supervisor trained in accordance with _________ (circle one) above.
Page 7
Warranty and Customer Service ADTRAN will replace or repair this product within five years from the date of shipment if the product does not meet its published specification, or if it fails while in service. For detailed warranty, repair, and return information, refer to the ADTRAN Equipment Warranty and Repair and Return Policy Proce- dure (see the last page of this manual).
Features ............................... 1-2 Quad T1/PRI Module Specifications...................... 1-3 Physical Description ............................1-3 Chapter 2 Installation..........................2-1 Before Installing the Quad T1/PRI Module....................2-1 Shipping Contents ............................. 2-1 Installing the Quad T1/PRI Module ......................2-1 Wiring ................................. 2-3 Chapter 3 Operation ..........................3-1 Overview ................................
Page 10
Pattern ..............................3-9 All ones ............................3-9 All zeros ............................3-9 QRSS ............................. 3-9 QRSS/RLB Results ..........................3-9 Clr ................................. 3-9 Inj ................................3-9 ATLAS Features Used with Quad T1/PRI Module................... 3-10 Factory Restore ..............................3-10 Quad T1/PRI Module User Manual 61200185L3-1...
Page 11
Table of Contents Run Self Test ..............................3-10 Mapping ................................3-10 Appendix A Dial Plan Interface Configuration..................A-1 Index ................................Index-1 61200185L3-1 Quad T1/PRI Module User Manual...
Page 12
Table of Contents Quad T1/PRI Module User Manual 61200185L3-1...
Chapter 1 QUAD T1/PRI MODULE OVERVIEW The Quad T1/PRI Module (P/N 1200185L3) is a member of the ATLAS fam- ily of integrated access products and provides four channelized T1 or Prima- ry Rate ISDN (PRI) interfaces. Each interface can operate independently in DS-1 or DSX-1 mode, and any port can serve as the primary or backup tim- ing source for the entire system.
(a NEBS-compliant version of the ATLAS 800 FUNCTIONAL DESCRIPTION The Quad T1/PRI Module installs into any available option slot in the ATLAS chassis. You can view the status of the module itself, as well as the circuits to which it interfaces, from the ATLAS front panel. Additional status information is available via the terminal menu, accessible through either a VT-100 terminal connected to the ATLAS Base Unit’s control port or through...
• Reports line performance data via SNMP in RFC1406 format • Trunk conditioning Quad T1/PRI Module Specifications Each port of the Quad T1/PRI Module conforms to the following specifica- tions: Line rate 1.544 Mbps, + 75 bps Capacity T1: 1 to 24 DS0s...
ADTRAN Technical Support (see the last page of this manual for pertinent information). If possible, keep the orig- inal shipping container for returning the Quad T1/PRI Module for repair or for verification of shipping damage.
Remove the cover plate from the appropriate option slot of the ATLAS rear panel. Slide the Quad T1/PRI Module into the option slot until the module is firmly positioned against the front of the chassis. Secure the thumbscrews at both edges of the module.
Chapter 2. Installation WIRING Each port of the Quad T1/PRI Module uses a single, eight-position modular jack to connect to the T1 or PRI circuit. Table 2-1 on page 2-3 gives the pinout for this jack. The required wiring connection is described here:...
Operation Chapter 3 OVERVIEW You can configure and control the Quad T1/PRI Module from a variety of sources, including the following: • The ATLAS front panel, providing minimal configuration and status support • The terminal menu, allowing detailed configuration, status, and diag- nostics •...
ODULES The ATLAS system controller automatically detects the presence of the Quad T1/PRI Module when it is installed in the system. To see the menus for the Quad T1/PRI Module via the terminal menu, use the arrow keys to scroll to the M menu and press to access the module choices.
Displays the type of module currently installed in the slot or the type of module you plan to install in the slot. If a Quad T1/PRI Module is installed, the Type field automatically defaults to T1/PRI-4 (the Quad T1/PRI Mod- ule).
Chapter 3. Operation Read security: 5 TATUS Read-only field that presents status information on the Quad T1/PRI Module. The following messages may display: The module is enabled and is responding to the system controller’s status NLINE polls. This is the normal response of the system.
Displays per-DS0 alarm status. These alarms usually indicate the failure to receive the protocol that has been configured for the DS0. Indicates the strength of the signal (in dB) received on the port. EVEL 61200185L3-1 Quad T1/PRI Module User Manual...
Page 30
A Severely Errored Second (SES) is a second with 320 or more error events OR one or more Out Of Frame events. SEFS Severely Errored Frame Seconds. Loss of Frame Count. LOFC Controlled Slip Seconds. Quad T1/PRI Module User Manual 61200185L3-1...
Page 31
Displays the port number. Write security: 3; Read security: 5 Accepts any alpha-numeric name up to 16 characters long, to uniquely identify each port on the Quad T1/PRI Module. Write security: 2; Read security: 5 RAME This field must be set to match the frame format of the circuit to which it is connected, available from the network supplier.
Page 32
Selects the Line Build Out (LBO) for the network interface. When connect- ing a Quad T1/PRI Module port to a DSX-1 interface, this parameter is typ- ically set to match the distance (in feet) between ATLAS and the device with which it is connecting.
Indicates sync and errors of received data pattern (Test Pattern and Remote ESULTS Loopback Results). Write security: 4; Read security: 5 Clears error counters on test pattern results menu. Write security: 4; Read security: 5 Injects errors into transmitted test pattern. 61200185L3-1 Quad T1/PRI Module User Manual...
ATLAS menu. , a submenu of the ATLAS main menu item T , executes both the Quad T1/PRI Module internal test and the ATLAS internal test. For additional information on S see the ATLAS User Manual.
To access these options, select D from the top level ATLAS menu (see Figure A-1.) The Write security level for all D options is 3. Figure A-1. Dial Plan Menus 61200185L3-1 Quad T1/PRI Module User Manual...
Page 36
QUAD T1/PRI MODULE: NETWORK TERMINATION/PRI When you are working in the network termination section of the D menu, when S is defined as a Quad T1/PRI Module, and when S is set to PRI, the following configuration options are available: WITCH Write security: 3;...
Page 38
QUAD T1/PRI MODULE: NETWORK TERMINATION/RBS When you are working in the network termination section of the D menu, when S is defined as a Quad T1/PRI Module, and when S is set to RBS, the following interface configuration options are available: IRST Write security: 3;...
Page 39
This option only displays if DID is set to E . If DID is D , then you NABLED ISABLED must define the trunk number. 61200185L3-1 Quad T1/PRI Module User Manual...
Page 40
CCEPT ber of 963-8615, set the trunk number to 963-8615. QUAD T1/PRI MODULE: USER TERMINATION/PRI When you are working in the user termination section of the D menu, when S is defined as a T1/PRI module, and when S...
Page 41
IALING ISABLED The Caller ID number must be specific (i.e., no “wild cards”). QUAD T1/PRI MODULE: USER TERMINATION/RBS When you are working in the user termination section of the D menu, when S is defined as a T1/PRI module, and when S...
Page 42
, then the following information must be NABLED defined: DID D Defines the number of digits ATLAS sends on to the user equipment. This IGITS field only displays if DID is set to E RANSFERRED NABLED Quad T1/PRI Module User Manual 61200185L3-1...
Page 43
This option only displays if DID is set UMBER to D . This item is optional. ISABLED The Caller ID number must be specific (i.e., no “wild cards”). 61200185L3-1 Quad T1/PRI Module User Manual...
Page 44
Appendix A. Dial Plan Interface Configuration A-10 Quad T1/PRI Module User Manual 61200185L3-1...
ETHOD DS0 A LARMS RUNK UMBER DS0 S TATUS (PRI) A-6 ONFIG ALLED IGITS RANSFERRED RAME DS0 A-6 IRST ETWORK PECIFIC ACILITY UMBER OF CCEPT ID A-7 UTGOING ALLER WITCH (RBS) A-7 ONFIG 61200185L3-1 Quad T1/PRI Module User Manual Index-1...
Page 46
1-3 EVEL tests 1-3 support 2-3 ERIAL UMBER TATUS technical support 2-3 test 3-8 test pattern 3-9 ELLOW LARM warranty vii, 2-3 wiring 2-3 NEBS compliance 1-2 Y2K iii operating the module 3-1 Index-2 Quad T1/PRI Module User Manual 61200185L3-1...
Page 47
Applications Engineering (800) 615-1176 Sales (800) 827-0807 Post-Sale Support Please contact your local distributor first. If your local distributor cannot help, please contact ADTRAN Technical Support and have the unit serial number available. Technical Support (888) 4ADTRAN Repair and Return If ADTRAN Technical Support determines that a repair is needed, Technical Support will coordinate with the Custom and Product Service (CAPS) department to issue an RMA number.