Summary of Contents for ADTRAN Quad T1

  • Page 1 Quad T1/PRI Module User Manual Part Number 1200185L3 61200185L3-1A December 1999...
  • Page 2 901 Explorer Boulevard P.O. Box 140000 Huntsville, AL 35814-4000 (256) 963-8000 © 1999 ADTRAN, Inc. All Rights Reserved. Printed in U.S.A.
  • Page 3 ADTRAN Year 2000 (Y2K) Readiness Disclosure ADTRAN has established a Year 2000 program to ensure that our products will correctly function in the new millennium. ADTRAN warrants that all products meet Year 2000 specifications regardless of model or revision. Information about ADTRAN's Year 2000 compliance program is available at the fol-...
  • Page 4 Part 68-compliant. See Chapter 2, Installation, for details. If your telephone equipment (Quad T1/PRI Module) causes harm to the telephone network, the telephone company may discontinue your service temporarily. If possible, they will notify you in advance.
  • Page 5 Affidavit Requirements for Connection to Digital Services • An affidavit is required to be given to the telephone company whenever digital terminal equipment without encoded analog content and billing protection is used to transmit digital signals containing encoded analog content which are intended for eventual conversion into voiceband analog signals and transmitted on the network.
  • Page 6 ( ) C. An independent training course (e.g., trade school or technical institution) recognized by the manufacturer/grantee of the equipment used to encode analog signals; or ( ) D. In lieu of the preceding training requirements, the operator(s)/maintainer(s) is (are) under the control of a supervisor trained in accordance with _________ (circle one) above.
  • Page 7 Warranty and Customer Service ADTRAN will replace or repair this product within five years from the date of shipment if the product does not meet its published specification, or if it fails while in service. For detailed warranty, repair, and return information, refer to the ADTRAN Equipment Warranty and Repair and Return Policy Proce- dure (see the last page of this manual).
  • Page 8 viii...
  • Page 9: Table Of Contents

    Features ............................... 1-2 Quad T1/PRI Module Specifications...................... 1-3 Physical Description ............................1-3 Chapter 2 Installation..........................2-1 Before Installing the Quad T1/PRI Module....................2-1 Shipping Contents ............................. 2-1 Installing the Quad T1/PRI Module ......................2-1 Wiring ................................. 2-3 Chapter 3 Operation ..........................3-1 Overview ................................
  • Page 10 Pattern ..............................3-9 All ones ............................3-9 All zeros ............................3-9 QRSS ............................. 3-9 QRSS/RLB Results ..........................3-9 Clr ................................. 3-9 Inj ................................3-9 ATLAS Features Used with Quad T1/PRI Module................... 3-10 Factory Restore ..............................3-10 Quad T1/PRI Module User Manual 61200185L3-1...
  • Page 11 Table of Contents Run Self Test ..............................3-10 Mapping ................................3-10 Appendix A Dial Plan Interface Configuration..................A-1 Index ................................Index-1 61200185L3-1 Quad T1/PRI Module User Manual...
  • Page 12 Table of Contents Quad T1/PRI Module User Manual 61200185L3-1...
  • Page 13: List Of Figures

    Figure 2-1. Installing the Quad T1/PRI Module ..................2-2 Figure 3-1. Modules Menu..........................3-2 Figure 3-2. Menu Tree for Quad T1/PRI Modules Menu ................. 3-2 Figure 3-3. Quad T1/PRI Menu Options ..................... 3-4 Figure 3-4. Network Loopback Test ......................3-9 Figure A-1.
  • Page 14 List of Figures Quad T1/PRI Module User Manual 61200185L3-1...
  • Page 15: List Of Tables

    List of Tables Table 2-1. Network Connection Pinout...................... 2-3 61200185L3-1 Quad T1/PRI Module User Manual...
  • Page 16 List of Tables Quad T1/PRI Module User Manual 61200185L3-1...
  • Page 17: Chapter 1 Introduction

    Chapter 1 QUAD T1/PRI MODULE OVERVIEW The Quad T1/PRI Module (P/N 1200185L3) is a member of the ATLAS fam- ily of integrated access products and provides four channelized T1 or Prima- ry Rate ISDN (PRI) interfaces. Each interface can operate independently in DS-1 or DSX-1 mode, and any port can serve as the primary or backup tim- ing source for the entire system.
  • Page 18: Nebs Compliance

    (a NEBS-compliant version of the ATLAS 800 FUNCTIONAL DESCRIPTION The Quad T1/PRI Module installs into any available option slot in the ATLAS chassis. You can view the status of the module itself, as well as the circuits to which it interfaces, from the ATLAS front panel. Additional status information is available via the terminal menu, accessible through either a VT-100 terminal connected to the ATLAS Base Unit’s control port or through...
  • Page 19: Quad T1/Pri Module Specifications

    • Reports line performance data via SNMP in RFC1406 format • Trunk conditioning Quad T1/PRI Module Specifications Each port of the Quad T1/PRI Module conforms to the following specifica- tions: Line rate 1.544 Mbps, + 75 bps Capacity T1: 1 to 24 DS0s...
  • Page 20 Chapter 1. Introduction Quad T1/PRI Module User Manual 61200185L3-1...
  • Page 21: Chapter 2 Installation

    ADTRAN Technical Support (see the last page of this manual for pertinent information). If possible, keep the orig- inal shipping container for returning the Quad T1/PRI Module for repair or for verification of shipping damage.
  • Page 22: Figure 2-1. Installing The Quad T1/Pri Module

    Remove the cover plate from the appropriate option slot of the ATLAS rear panel. Slide the Quad T1/PRI Module into the option slot until the module is firmly positioned against the front of the chassis. Secure the thumbscrews at both edges of the module.
  • Page 23: Wiring

    Chapter 2. Installation WIRING Each port of the Quad T1/PRI Module uses a single, eight-position modular jack to connect to the T1 or PRI circuit. Table 2-1 on page 2-3 gives the pinout for this jack. The required wiring connection is described here:...
  • Page 24 Chapter 2. Installation Quad T1/PRI Module User Manual 61200185L3-1...
  • Page 25: Chapter 3 Operation

    Operation Chapter 3 OVERVIEW You can configure and control the Quad T1/PRI Module from a variety of sources, including the following: • The ATLAS front panel, providing minimal configuration and status support • The terminal menu, allowing detailed configuration, status, and diag- nostics •...
  • Page 26: Modules

    ODULES The ATLAS system controller automatically detects the presence of the Quad T1/PRI Module when it is installed in the system. To see the menus for the Quad T1/PRI Module via the terminal menu, use the arrow keys to scroll to the M menu and press to access the module choices.
  • Page 27: Slt

    Displays the type of module currently installed in the slot or the type of module you plan to install in the slot. If a Quad T1/PRI Module is installed, the Type field automatically defaults to T1/PRI-4 (the Quad T1/PRI Mod- ule).
  • Page 28: Status

    Chapter 3. Operation Read security: 5 TATUS Read-only field that presents status information on the Quad T1/PRI Module. The following messages may display: The module is enabled and is responding to the system controller’s status NLINE polls. This is the normal response of the system.
  • Page 29: Info

    Displays per-DS0 alarm status. These alarms usually indicate the failure to receive the protocol that has been configured for the DS0. Indicates the strength of the signal (in dB) received on the port. EVEL 61200185L3-1 Quad T1/PRI Module User Manual...
  • Page 30 A Severely Errored Second (SES) is a second with 320 or more error events OR one or more Out Of Frame events. SEFS Severely Errored Frame Seconds. Loss of Frame Count. LOFC Controlled Slip Seconds. Quad T1/PRI Module User Manual 61200185L3-1...
  • Page 31 Displays the port number. Write security: 3; Read security: 5 Accepts any alpha-numeric name up to 16 characters long, to uniquely identify each port on the Quad T1/PRI Module. Write security: 2; Read security: 5 RAME This field must be set to match the frame format of the circuit to which it is connected, available from the network supplier.
  • Page 32 Selects the Line Build Out (LBO) for the network interface. When connect- ing a Quad T1/PRI Module port to a DSX-1 interface, this parameter is typ- ically set to match the distance (in feet) between ATLAS and the device with which it is connecting.
  • Page 33: Figure 3-4. Network Loopback Test

    Indicates sync and errors of received data pattern (Test Pattern and Remote ESULTS Loopback Results). Write security: 4; Read security: 5 Clears error counters on test pattern results menu. Write security: 4; Read security: 5 Injects errors into transmitted test pattern. 61200185L3-1 Quad T1/PRI Module User Manual...
  • Page 34: Run Self Test

    ATLAS menu. , a submenu of the ATLAS main menu item T , executes both the Quad T1/PRI Module internal test and the ATLAS internal test. For additional information on S see the ATLAS User Manual.
  • Page 35: Appendix A Dial Plan Interface Configuration

    To access these options, select D from the top level ATLAS menu (see Figure A-1.) The Write security level for all D options is 3. Figure A-1. Dial Plan Menus 61200185L3-1 Quad T1/PRI Module User Manual...
  • Page 36 QUAD T1/PRI MODULE: NETWORK TERMINATION/PRI When you are working in the network termination section of the D menu, when S is defined as a Quad T1/PRI Module, and when S is set to PRI, the following configuration options are available: WITCH Write security: 3;...
  • Page 37 Nortel Private Network – AT&T Megacom • Nortel InWats – AT&T Accunet • Nortel OutWats • AT&T Long Distance • Nortel Foreign Exchange • AT&T International-800 • Nortel Tie Trunk • AT&T Dial-It 900/Multiquest 61200185L3-1 Quad T1/PRI Module User Manual...
  • Page 38 QUAD T1/PRI MODULE: NETWORK TERMINATION/RBS When you are working in the network termination section of the D menu, when S is defined as a Quad T1/PRI Module, and when S is set to RBS, the following interface configuration options are available: IRST Write security: 3;...
  • Page 39 This option only displays if DID is set to E . If DID is D , then you NABLED ISABLED must define the trunk number. 61200185L3-1 Quad T1/PRI Module User Manual...
  • Page 40 CCEPT ber of 963-8615, set the trunk number to 963-8615. QUAD T1/PRI MODULE: USER TERMINATION/PRI When you are working in the user termination section of the D menu, when S is defined as a T1/PRI module, and when S...
  • Page 41 IALING ISABLED The Caller ID number must be specific (i.e., no “wild cards”). QUAD T1/PRI MODULE: USER TERMINATION/RBS When you are working in the user termination section of the D menu, when S is defined as a T1/PRI module, and when S...
  • Page 42 , then the following information must be NABLED defined: DID D Defines the number of digits ATLAS sends on to the user equipment. This IGITS field only displays if DID is set to E RANSFERRED NABLED Quad T1/PRI Module User Manual 61200185L3-1...
  • Page 43 This option only displays if DID is set UMBER to D . This item is optional. ISABLED The Caller ID number must be specific (i.e., no “wild cards”). 61200185L3-1 Quad T1/PRI Module User Manual...
  • Page 44 Appendix A. Dial Plan Interface Configuration A-10 Quad T1/PRI Module User Manual 61200185L3-1...
  • Page 45: Index

    ETHOD DS0 A LARMS RUNK UMBER DS0 S TATUS (PRI) A-6 ONFIG ALLED IGITS RANSFERRED RAME DS0 A-6 IRST ETWORK PECIFIC ACILITY UMBER OF CCEPT ID A-7 UTGOING ALLER WITCH (RBS) A-7 ONFIG 61200185L3-1 Quad T1/PRI Module User Manual Index-1...
  • Page 46 1-3 EVEL tests 1-3 support 2-3 ERIAL UMBER TATUS technical support 2-3 test 3-8 test pattern 3-9 ELLOW LARM warranty vii, 2-3 wiring 2-3 NEBS compliance 1-2 Y2K iii operating the module 3-1 Index-2 Quad T1/PRI Module User Manual 61200185L3-1...
  • Page 47 Applications Engineering (800) 615-1176 Sales (800) 827-0807 Post-Sale Support Please contact your local distributor first. If your local distributor cannot help, please contact ADTRAN Technical Support and have the unit serial number available. Technical Support (888) 4ADTRAN Repair and Return If ADTRAN Technical Support determines that a repair is needed, Technical Support will coordinate with the Custom and Product Service (CAPS) department to issue an RMA number.

This manual is also suitable for:

Quad pri

Table of Contents