Figure 19. Self-Test Options Screen - ADTRAN E220 HFAC HDSL Installation And Maintenance Manual

Hdsl / hdsl2 fuse alarm control unit
Hide thumbs Also See for E220 HFAC HDSL:
Table of Contents

Advertisement

Self-Test Options Screen
By selecting item 7 from the Main Menu, the Self-
Test Options Screen (Figure 19) is presented. From
this screen, a self-test for the HTU-C, HTU-R, and
HFAC controller can be initiated. To initiate a self-
test, press the desired test number followed by a T.
Upon completion of the test, results will be presented.
These tests are useful in diagnosing suspect hardware
and circuits.
11/23/99
00:26:44
61221051L1-5A
SELF-TEST
[ SLOT = 8
1.
INITIATE HTU-C AND HTU-R SELF-TESTS
2.
INITIATE HFAC CONTROLLER SELF-TEST
Press :
"nnS"
to select slot
"nT"
to select desired test
"M"
to return to Main Menu :

Figure 19. Self-Test Options Screen

61221051L1-5, Issue 1
NOTE
Momentary communications loss between the
HFAC and HTU-C units will occur when the
HFAC is first plugged in, or when HFAC self-
test is executed. If HFAC communications
alarms are not disabled, a momentary alarm
may also be generated.
SHELF ADDRESS = 00
]
17

Advertisement

Table of Contents
loading

This manual is also suitable for:

E220 hfac hdsl2

Table of Contents