Download Print this page
Hide thumbs Also See for 3192 H2TU-C:

Advertisement

Quick Links

HDSL2
LED STATUS
3192 H2TU-C
Label Indications
STAT
Off
4
Green Flashing
P/N: 1223004L4
Green
CLEI: T1I3AEYE_ _
Off
DLOS
Red
RLOS
Off
Red
HLOS
Off
1223004L4
Red
4
Red Flashing
Off
DSL
Green
Yellow
Red
Flashing
LBK
Off
HCRC
LINE
CODE
4
Yellow Flashing
Yellow
STAT
DSX EQ
DLOS
TX
Off
ARM/
LBK
Yellow
RLOS
Green
RX
4
HLOS
Green Flashing
Off
B8ZS
DSL
Green
TX
COMPLIANCE
HCRC
(Y)
This product is intended for installation in restricted access locations only.
RX
ARM
/LBK
WARNING:
(G)
DSX MON
B8ZS
CAUTION:
This product provides span powering voltage (negative only with respect to ground, –190 VDC nominal, GFI
protection < 5 mA) and meets all requirements of Bellcore GR-1089-CORE (Class A2), ANSI T1.418-2002.
This product is NRTL listed to the applicable UL standards.
HDSL2 LOOP GUIDELINES FOR OPTIMUM OPERATION
Cable pairs must be non-loaded
No single Bridged Tap > 2 kft.; Total Bridged Tap < 2.5 kft.
Loop Resistance:  
Attenuation:  30 dB
Impulse noise < 52 dBrnF (F filter)
Wideband noise < 47 dBrnF (F filter)
Margin  6 dB
Longitudinal Noise (Power Influence):
C A U T I O N !
80 dBrnC:
80-90 dBrnC: marginal
SUBJECT TO ELECTROSTATIC DAMAGE
> 90 dBrnC:
OR DECREASE IN RELIABILITY
HANDLING PRECAUTIONS REQUIRED
©2014 ADTRAN, Inc.
All Rights Reserved.
Description
Indicates a loss of power or blown fuse has occurred
Attempting to acquire HDSL2 synchronization with the H2TU-R
Normal operation; HDSL2 synchronization is achieved with the H2TU-R
DSX-1 signal is present and synchronized with no errors
No DSX-1 signal, or signal is present with errors
DS1 signal from CPE is present at H2TU-R with no errors
No DS1 signal from CPE at H2TU-R, or present with errors
Normal Operation; end-to-end HDSL2 synchronization good
Loss of end-to-end HDSL2 synchronization on the 2-wire Loop
GFI or overcurrent condition detected
HDSL2 synchronization has not been achieved on the 2-wire Loop
Normal operation; signal margin is optimum (6 dB) on the 2-wire Loop
Marginal operation; signal margin is 1-5 dB on the 2-wire Loop
Margin dB; severely impaired HDSL2 operation
If attenuation (LOSS on Current System Status Screen) is  30 dB the
solid. If attenuation is > 30 dB, the
LED flashes green, yellow, or red as determined by
DSL
the signal quality
Normal operation; No HDSL2 CRC errors detected by this unit within the last 30 minutes
on the 2-wire Loop
One or more HDSL2 CRC errors are being detected by this unit on the 2-wire Loop
Four or more HDSL2 CRC errors have been detected on the 2-wire Loop within the last 30
minutes. The LED remains lit for 30 minutes. If no HDSL2 CRC errors occur within a 
rolling 30 minute interval, the LED extinguishes.
Unit is not in the armed or loopback state
Unit is an armed state
A loopback is active on this specific unit
A loopback is active on the H2TU-R
Unit is receiving AMI line code
Unit is receiving B8ZS line code
Up to –200 VDC may be present on
Configuration Code
telecommunications wiring.
The DSX-1 interface is intended for
Power Code
connection to intra-building wiring
Telecommunication Code (TC)
only. Ensure Chassis ground is
properly connected.
Installation Code (IC)
acceptable
unacceptable
For more information, refer to the Installation and Maintenance Practice (P/N 61223004L4-5) available online at www.adtran.com.
HDSL2
3192 H2TU-C
ON-BOARD OPTIONS
The following options can be accessed on the circuit board:
Line Build Out (LBO) Switches
Use the DIP switch SW5 to select a distance of: 0-133 (default),
133-266, 266-399, or 399-533 feet.
Card Edge Pinouts
Pin #
1
2
5
8
9
10
LED remains
* The HDSL2 Loop is full duplex, capable of simultaneously sending and receiving data.
DSL
FRONT PANEL OPTIONS
The following options can be accessed on the front panel:
Pushbuttons
LBK
To Loop Up:
H2TU-C
H2TU-R
To Loop Down:
H2TU-C
H2TU-R
LINE CODE
Input
Output
F
C
DSX EQ Splitting Jacks
X
DSX-1 transmit toward the local loop (intrusive)
TX
DSX-1 receive from the local loop (intrusive)
A
RX
DSX Monitor Jacks
DSX-1 transmit toward the local loop (nonintrusive)
TX
DSX-1 receive from the local loop (nonintrusive)
RX
RS-232 DB-9 Connector
Used to access performance monitoring data, perform loopbacks, and provision units via VT100 emulation
applications, such as HyperTerminal. There are two terminal emulation modes:
.
Update
CTRL+T
Manual Update
commands are available in this mode.
Real-Time Update
placement and screen highlighting are enabled.
Provision terminal port for VT100:
bits; no parity (none); one stop bit. When using a PC with terminal emulation software, be sure to disable any
power saving programs.
Document P/N: 61223004L4-22G
Function
Pin #
R TX DSX (In from DSX)
A
R1 RX DSX (Out to DSX)
B
GND
H
–48 V
J
R HDSL2 Loop*
K
Fuse Alarm (to Alarm Module)
To perform loopback functions, use the following methods:
Press and Hold LBK Button:
Less than 3 seconds
More than 3 seconds
Press and Hold LBK Button:
Less than 3 seconds
Less than 3 seconds
To release the active loopback, press the
pushbutton until the
LBK
Press this button to provision for AMI or B8ZS (default) line coding. A Green
indicates B8ZS line code.
toggles between modes.
Mode: Press the spacebar three times to manually update the screen. Print screen and log files
Mode: The default mode. Print screen and log file commands not available. Cursor
Data Rate = 1.2 to 19.2 kbps; Asynchronous Data Format = eight data
Issue Date: January 2014
0
ON
ON
ON
133
ON
ON
OFF
266
ON
OFF
ON
O
O
O
1
1
1
2
2
2
3
3
3
N
N
N
399
ON
OFF
OFF
533
OFF
ON
ON
Function
T TX DSX (In from DSX)
T1 RX DSX (Out to DSX)
DCV LOS (to Alarm Module)
Frame Ground
T HDSL2 Loop*
ARM/LBK LED Shows:
Green
Flashing Green
ARM/LBK LED Shows:
Off
Off
LED extinguishes.
ARM/LBK
LED
B8ZS
and
Manual Update
Real-Time

Advertisement

loading

Summary of Contents for ADTRAN 3192 H2TU-C

  • Page 1 80-90 dBrnC: marginal SUBJECT TO ELECTROSTATIC DAMAGE  > 90 dBrnC: unacceptable OR DECREASE IN RELIABILITY HANDLING PRECAUTIONS REQUIRED ©2014 ADTRAN, Inc. All Rights Reserved. For more information, refer to the Installation and Maintenance Practice (P/N 61223004L4-5) available online at www.adtran.com.
  • Page 2 NOTE: If NIU is enabled, then the H2TU-R can be in network loopback when the H2TU-C loop-up codes are sent. Warranty: ADTRAN will replace or repair this product within the warranty period if it does not meet its published specifications or fails while in service. ...

This manual is also suitable for: