Assembly - Pronomic 90P Original Instructions Manual

Parts for stationary lifter
Table of Contents

Advertisement

2 Assembly

Protective footwear should be used when assembling the stationary lifter, to prevent injuries if
parts are dropped.
It is important that the modules are installed according to this specifications.
Confirm the design of the structure that the stationary lifter is mounted to. Consider the load
diagrams starting on page 10.
1. In position A in the picture above. Mount the cross-member to the structure using 8 M8
bolts grade 8.8. At least 30mm of thread is needed inside of the cross-member. Do not
tighten to hard, use 15 Nm.
2. In position B in the picture above. Screw bars should be positioned with the lowest screw at
least 245mm from the bottom end of the column. For 90/125/130P the distance should be
at least 145mm from bottom end of the column. The screw bars should be fastened with 4
M8 nyloc nuts against the structure (2 nuts for 90/125/130P). Do not tighten to hard, use 15
Nm.
3. Position the power pack in such a way that the main switch can be reached. Make sure the
power cable does not enter the path of the load carrier. Make sure the power pack is well
protected against external damage.
4. Attach the load carrier with the supplied screws and washers in the slide of the column.
________________________________________________________________________________
3 – Stationary lifter (90/125/130/175/225P)

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

125p130p175p225p

Table of Contents