Downloading The Font Data; Bks-R6010 (Ver.2.00 Or Higher) - Sony BKS-R6010 Maintenance Manual

Universal lcd remote panel
Hide thumbs Also See for BKS-R6010:
Table of Contents

Advertisement

1-8. Downloading the Font Data

<BKS-R6010 (Ver.2.00 or higher)>
The BKS-R6010 of ver. 2.00 or higher supports the
multilingual display. Make sure that the font data corre-
sponding to the language must be downloaded to display
the characters correctly. The font data currently available
are as follows.
Font data type
Supported language
TYPE1 English, Japanese
TYPE2 English, Chinese (Simplified Chinese)
Download the font data corresponding to the language
from the designated download site.
The font data are also stored in the CD-ROM supplied with
the IXS-6600-C/IXS-6700-C.
n
The type1 font data is installed as the factory default
setting. This font data corresponds to the English and
Japanese areas.
Preparation
1. Check that the network cable is connected to the
network connecter NETWORK of the unit and
connected to the Ethernet Switch. (Fig. 1)
Ethernet Switch
Network cable
(straight)
NETWORK
BKS-R6010
Fig. 1
2. Configure the network setting of the PC used to
download the data to the one that can be connected to
the unit.
m
. Check if the subnet mask corresponds to that of the
unit.
. Check if the upper three digits of the IP address
corresponds to those of the unit.
3. Check the IP address of the unit.
The IP address can be checked in the secondary station
terminal menu "V: DISPLAY UNIT STATUS" or
with the status indicator of the unit.
For the secondary station terminal menu, refer to the
system setup manual, and for the status indicator, refer
to the installation manual.
BKS-R6010 MM
Network cable
(straight)
PC
Standard operation time
The standard time for each operation is as follows.
Trans
Writing to
ferring
the flash
data
memory
About 6
About 3
minutes
minutes
n
The time shown above is just a standard. The time may
differ depending on the working environment.
Procedure
1. Turn on the power of the PC.
2. Copy the font data to be downloaded to the PC.
3. Start the terminal software on the PC.
4. Connect (link) the PC to the unit via Ethernet.
Set the same IP address as that of the unit for the TCP/
IP of the terminal software, and set the Port number to
1001.
For checking the IP address of the unit, refer to "2-2.
Checking Equipment Status" of the Installation
manual.
5. Check that the startup screen is displayed in the
terminal menu.
SONY ROUTING SYSTEM BKS-6010 V2.00
ITEM
ROM CHECK SUM
AEDA
S-BUS LINK TERMINATE
OK
REAL TIME CLOCK
OK
STARTED
6. Send the font data from the terminal software to the
unit.
7. When the data is written to the flash memory after the
data is sent, the unit automatically restarts.
n
While writing the data to the flash memory (for about
3 minutes) after transferring the data, all LCD displays
on the panel turn blue. This is not a failure.
Do not turn off the power while all the LCD displays
on the panel light in blue (the data is written to the
flash memory).
8. Exit the terminal software.
9. Check that the unit restarts normally.
Restarting
Total
About 1
About 10
minutes
minutes