Technical Data - GEM R629 eSyLite Operating Instructions Manual

Motorized diaphragm valve
Table of Contents

Advertisement

6 Technical data

6.1 Medium
Working medium:
6.2 Temperature
Media temperature:
Ambient temperature:
6.3 Pressure
Operating pressure:
Pressure/temperature
correlation:
www.gemu-group.com
Corrosive, inert, gaseous and liquid media which have no negative impact on the physical and
chemical properties of the body and diaphragm material.
The valve will seal in both flow directions up to full operating pressure (gauge pressure).
PVC-U, grey
ABS
Code 1
Code 4
10 to 60 °C
-10 to 60 °C
PVC-U, grey
ABS
Code 1
Code 4
10 to 50 °C
-10 to 50 °C
If the emergency power module is used (control module code A1, A2), the maximum ambient tem-
perature is reduced to 40 °C.
0 to 6 bar
All pressures are gauge pressures. Operating pressure values were determined with static operat-
ing pressure applied on one side of a closed valve. Sealing at the valve seat and atmospheric seal-
ing is ensured for the given values.
Information on operating pressures applied on both sides and for high purity media on request.
Valve body material
MG
Materials
Code
10
PVC-U
1
PP
5 / N5
PP-H
5 / N5
PVDF
20
20,
PVC-U
1
25, 40
ABS
4
PP-H
71
PVDF
75
Permissible operating pressure in bar
The pressure rating (PN) depends on the connection code.
Data for extended temperature ranges on request. Please note that the ambient temperature and media tem-
perature generate a combined temperature at the valve body which must not exceed the above values.
PP, rein-
PVDF
forced / PP-
H, natural
Code 5 / N5
Code 20
5 to 80 °C
-10 to 80 °C
PP, rein-
PVDF
forced / PP-
H, natural
Code 5 / N5
Code 20
5 to 50 °C
0 to 50 °C
Temperature in °C (valve body)
-1
±0
5
10
20
0
-
-
-
6.0
6.0
-
-
6.0
6.0
6.0
-
-
6.0
6.0
6.0
6.0
6.0
6.0
6.0
6.0
-
-
-
6.0
6.0
6.0
6.0
6.0
6.0
6.0
-
-
6.0
6.0
6.0
6.0
6.0
6.0
6.0
6.0
9 / 37
6 Technical data
Inliner PP-H
Inliner PVDF /
grey / outliner
outliner PP,
PP, reinforced
reinforced
Code 71
5 to 80 °C
-10 to 80 °C
Inliner PP-H
Inliner PVDF /
grey / outliner
outliner PP,
PP, reinforced
reinforced
Code 71
5 to 50 °C
-10 to 50 °C
25
30
40
50
60
6.0
4.8
3.6
2.1
0.9
6.0
5.1
4.2
3.3
2.4
6.0
5.1
4.2
3.3
2.4
6.0
5.4
4.8
4.3
3.8
6.0
6.0
6.0
3.5
1.5
6.0
6.0
6.0
4.0
2.0
6.0
6.0
6.0
5.5
4.0
6.0
6.0
6.0
6.0
6.0
Code 75
Code 75
70
80
-
-
1.6
0.9
1.6
0.9
3.2
2.8
-
-
-
-
2.7
1.5
5.4
4.7
GEMÜ R629

Advertisement

Table of Contents
loading

Table of Contents