12.10 Quiet Operation

(For Cooling Operation or cooling region of Soft Dry Operation)
To provide quiet cooling operation condition.
Once the Quiet Operation is set at the remote control, the Quiet LED brightness will be dimmed. The sound level
will reduce around 2dB(A) for Lo fan speed or 3dB(A) for Hi/Me fan speed against the present operation sound
level.
Dew formation become severe at Quite Lo Cool, therefore Quiet Lo cool operated only for 1 hour 30 minutes (1
hour QLo, 30 minutes QLo + 80rpm)(for A9MKD and A12MKD) and Quiet Lo cool operated only 1 hour 30
minutes (1 hour QLo, 30 minutes QLo + 50 rpm) (for A18MKD, A24MKD and A28MKD).
Manual Airflow Direction:
RPM control during Lo cool
o
(For A9MKD and A12MKD)
(For A18MKD, A24MKD and A28MKD)
RPM control during Hi & Me cool
o
Auto Fan Speed
Quiet operation stops when:
Quiet button is pressed again.
o
Stopped by OFF/ON operation button.
o
Timer OFF activates.
o
Operation mode button is changed.
o