12.9 Powerful Operation

To achieve the setting temperature quickly.
(Cooling and Soft Dry Operation condition)
When Powerful operation is set, the setting temperature will be automatically decreased 3°C internally against
the present setting temperature (Lower temperature limit: 16°C).
This operation automatically will be running under SHi Fan Speed (Cooling).
Vertical Airflow Direction:-
o In "Manual" setting, the vane will automatically shift down 10° lower than previous setting.
o In "Auto" setting, the vane will automatically swing up and down. However the lower limit will be shifted 10°
downward.
(Heating Operation condition)
When Powerful operation is set, the setting temperature will be automatically increased 3°C against the present
setting temperature (Higher temperature: 30°C).
The Fan Speed will shift as shown below:
Vertical Airflow Direction:-
o In "Manual" setting, the vane will automatically shift down 5° lower than previous setting.
o In "Auto" setting, the vane will automatically shift between upper and lower limit depending on the intake air
temperature as Heating Mode, Airflow Direction Auto-Control. However the upper and lower limit will be
shifted 5° downward.
Powerful operation stops when:-
o Powerful operation has operate for 15 minutes.
o Powerful button is pressed again.
o Quiet button is pressed
o Stopped by OFF/ON operation button.
o Timer OFF activates.
o Operating mode is changed.