Quiet Operation (Heating); Powerful Mode Operation; Timer Control - Panasonic CS-CZ25ZKE Service Manual

Table of Contents

Advertisement

14.6 Quiet Operation (Heating)

A. Purpose
To provide quiet heating operation compare to normal operation.
B. Control condition
a. Quiet operation start condition
When "FAN SPEED/QUIET" button at remote control is pressed continuously until QUIET will be shown
on remote control display.
b. Quiet operation stop condition
1. When one of the following conditions is satisfied, quiet operation stops:
a. POWERFUL button is pressed.
b. Stop by OFF/ON switch.
c. Timer "off" activates.
d. When FAN SPEED/QUIET button is pressed again and fan speed is change to Low.
e. +8/15°C Heat is activated.
2. When quiet operation is stopped, operation is shifted to normal operation with previous setting.
3. When operation mode is changed, quiet operation is shifted to quiet operation of the new mode.
4. During quiet operation, if timer "on" activates, quiet operation maintains.
5. After off, when on back, quiet operation is memorised.
C. Control contents
1. Fan speed is changed to QLo.

14.7 Powerful Mode Operation

When the powerful mode is selected, the internal setting temperature will shift lower up to 1°C (for Cooling/Soft
Dry) or higher up to 1°C (for Heating) than remote control setting temperature to achieve the setting temperature
quickly.

14.8 Timer Control

There are 2 sets of ON and OFF timer available to turn the unit ON or OFF at different preset time.
If more than one timer had been set, the upcoming timer will be displayed and will activate in sequence.
14.8.1.1
ON Timer Control
ON timer 1 and ON timer 2 can be set using remote control, the unit with timer set will start operate earlier than
the setting time.
This is to provide a comfortable environment when reaching the set ON time.
60 minutes before the set time, indoor (at fan speed of Lo-) and outdoor fan motor start operate for 30 seconds to
determine the indoor intake air temperature and outdoor air temperature in order to judge the operation starting
time.
From the above judgment, the decided operation will start operate earlier than the set time as shown below.
Indoor intake air
temperature (
30
25
5 min
14.8.2
OFF Timer Control
OFF timer 1 and OFF timer 2 can be set using remote control, the unit with timer set will stop operate at set time.
o
C)
15 min
10 min
Outdoor air
o
30
35
(
C)
temperature (
Cooling/Soft Dry/Fan
Indoor intake air
o
temperature (
C)
15
5
35 min
o
C)
63
25 min
30 min
Outdoor air
o
0
5
(
C)
temperature (
Heating
o
C)

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Cu-cz25zkeCs-cz35zkeCu-cz35zke

Table of Contents