Powerful Operation - Panasonic CS-A12PKD Service Manual

Hide thumbs Also See for CS-A12PKD:
Table of Contents

Advertisement

13.8.2 Manual Control
When the horizontal airflow direction is set to Manual using the remote control, the automatic airflow is released
and the airflow direction vane move left and right in the range shown in the diagram.
The louver can be adjusted by pressing the button to the desired vane position.
When stopped with remote control, the vanes is reset and stopped at reset position.
For CS-A9PK and CS-A12PK
Pattern
Airflow Direction Patterns at
Remote Control
Vane Angle (°)
For CS-A18PK, CS-A24PK and CS-A28PK
Pattern
Airflow Direction Patterns at
Remote Control
Vane Angle (°)

13.9 Powerful Operation

To achieve the setting temperature quickly.
(Cooling and Soft Dry Operation condition)
When Powerful operation is set, the setting temperature will be automatically decreased 3°C internally against
the present setting temperature (Lower temperature limit: 16°C).
This operation automatically will be running under SHi Fan Speed (Cooling).
Vertical Airflow Direction:-
o In "Manual" setting, the vane will automatically shift down 10° lower than previous setting.
o In "Auto" setting, the vane will automatically swing up and down. However the lower limit will be shifted 10°
downward.
1
2
25
50
1
2
20
40
67
3
4
37.5
12.5
3
4
30
10
5
0
5
0