14.10 Quiet Operation (Heating)

A. Purpose
To provide quiet heating operation compare to normal operation.
B. Control condition
a. Quiet operation start condition
When "FAN SPEED/QUIET" button at remote control is pressed continuously until QUIET will be shown
o
on remote control display.
b. Quiet operation stop condition
1
When one of the following conditions is satisfied, quiet operation stops:
a. POWERFUL button is pressed.
b. Stop by OFF/ON switch.
c.
Timer "off" activates.
d. When FAN SPEED/QUIET button is pressed again and fan speed is change to Low.
e. Sleep mode timer delay OFF.
2
When quiet operation is stopped, operation is shifted to normal operation with previous setting.
3
When operation mode is changed, quiet operation is shifted to quiet operation of the new mode.
4
During quiet operation, if timer "on" activates, quiet operation maintains.
5
After off, when on back, quiet operation is memorized.
C. Control contents
1
Fan speed is changed to QLo.

14.11 Powerful Mode Operation

When the powerful mode is selected, the internal setting temperature will shift lower up to 2°C (for Cooling/Soft
Dry) or higher up to 3.5°C (for Heating) than remote control setting temperature for 20 minutes to achieve the
setting temperature quickly.
14.12 nanoe
X Operation
Generate nanoe™ X (water wrapped ion particle) to moisturize skin, provide deodorization & sterilization effect.
nanoe™ X operation start condition
During unit running at any operation mode, if nanoe™ X operation is activated, combination operation
o
(operation mode + nanoe™ X operation) starts.
During unit is OFF, if nanoe™ X operation is activated, nanoe™ X individual operation starts.
o
nanoe™ X operation stop condition
When OFF/ON button is pressed to stop the operation.
o
When nanoe™ X button is pressed.
o
When OFF Timer activates.
o
nanoe™ X operation pause condition
When indoor fan stop (during deice, odor cut control, thermostat off, etc.). nanoe™ X operation resume after
o
indoor fan restarts.
When indoor intake temperature ≥ 35°C and ≤ 5°C. nanoe™ X operation resume after indoor intake
o
temperature < 35°C or ≥ 5°C continuously for 6 minutes.
Indoor fan control
During any operation mode combines with nanoe™ X operation, fan speed follows respective operation
o
mode. However, nanoe™ X system enabled when fan speed ≥ 360 rpm to ensure proper negative ion
distribution, nanoe™ X system disabled when fan speed < 360 rpm.
During nanoe™ X individual operation, fan speed follow remote control setting. Auto Fan Speed for
o
nanoe™ X individual operation is cooling medium fan. Powerful & Quiet is disabled during nanoe™ X.
Airflow direction control
During any operation mode combines with nanoe™X operation, airflow direction follows respective operation
o
mode.
During nanoe™ X individual operation, Air Swing follow remote control setting.
o