asecos FX Series User Manual

Recirculating air filter storage cabinet
Hide thumbs Also See for FX Series:

Advertisement

Quick Links

EP.V.30055 · 03/2016
USER MANUAL
Recirculating air filter storage cabinet
EN 14470-1
EN
EP.V. 10367
10/2013
5
5

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the FX Series and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for asecos FX Series

  • Page 1 EP.V.30055 · 03/2016 EP.V. 10367 10/2013 USER MANUAL Recirculating air filter storage cabinet EN 14470-1...
  • Page 2 YOUR PERSONAL DOCUMENTATION TO THE asecos SAFET Y CABINET Dear Customer, you have made a decisive investment in safety for your company by purchasing this asecos safety storage cabinet. You now own an innovative product made of top-quality materials guaranteeing the highest quality standards.
  • Page 3: Table Of Contents

    6. ERECTION OF THE RECIRCULATING AIR FILTER MODULE ......14 Your asecos team 6.1.
  • Page 4: Notes • Guidelines • Guarantee

    fire, only by an authorised asecos employee (refer also to our service brochure regarding this). In addition, we recommend that you carry out a daily and monthly functional check: 0–35 °C...
  • Page 5: Transport

    4. TRANSPORT Titling onto the side wall • is only possible with the optionally available tilting bracket (order no. HF.V.27665) CAUTION: Transport the cabinet in an upright position on a pallet truck, tied and secured against slipping, until Q-Mover the final place of installation is reached. The transport locks in the door joints may only be removed •...
  • Page 6: Anti Tilt Device Model Fx30

    FX CLASSIC 30 with adjusting aids in plinth 4× max. 2× (!) FX CLASSIC 30 without adjusting aids made of metal! 5.2. ANTI TILT DEVICE MODEL FX30 6.2. FALL PROTECTION OF THE RECIRCULATING AIR FILTER MODULE CAUTION: Use for this the enclosed anti-tilt angle and position this in the CAUTION: middle of the cabinet cover.
  • Page 7: Commissioning

    These values are preset and can only be changed by an SE RVIC E ME N U U SE R ME N U asecos service technican. FX CLASSIC 90 Ventilation wheel for technical ventilation Volum etric flow FX PEGASUS 90 clear the filled out...
  • Page 8: Filter Check And Filter Change

    Follow the instructions on the display! PLEASE NOTE! Only the original asecos accessories and spare parts are accepted! Leaks: Otherwise the costumer's guarantee claim against the manufacturer expires and • Liquid in the sump is to be collected using suitable means.
  • Page 9: Drawers, Second Storage Level

    Doors with arrest system Doors closable only by hand The height of the drawers in safety storage cabinets may be adjusted only by authorised asecos employees, since the safe retraction of the drawers in case of fire must be guaranteed! 10.3.
  • Page 10 Battery replacement =4× =4× =4× Changing the closing times with the aid of the jumper 1: 15 sec 2: 60 sec 3: 4.5 min CAUTION: The electrical cable on the housing may not come into contact with the locking linkage of the cabinet!
  • Page 11: Appendix 1: Technical Data

    APPENDIX 1: TECHNICAL DATA Int. ∆p ∆p (EK5/AK4 09-10) (EK5/AK4 09-10) FX90.229.120.WDAC 1193 2294 1050 1647 — — — — FX90.229.090.WDAC 2294 1647 22,73 — — — — FX90.229.060.WDAC / FX90.229.060.WDACR 2294 1647 — — — — FX90.229.120.MV 1193 2294 450/450 522 1647 —...
  • Page 12: Appendix 2: Technical Drawings

    APPENDIX 2: TECHNICAL DRAWINGS Front view Side view Selectional view Front view Side view Selectional view Draufsicht Draufsicht 1193 1193 Recirculating air filter module Recirculating air filter module Tray shelf, metal-free Tray shelf, metal-free Storage box Drawer (heavy-duty) 1007 Shelf Drawer Tray shelf (bottom collecting sump used as storage area)
  • Page 14 GmbH Abt. Kundendienst Weiherfeldsiedlung 16-18 D-63584 Gründau Fax: +49 60 51 – 92 20-10 www.asecos.com Ihr Fachhändler: Your partner: Uw partner: Votre partenaire : Su distribuidor: su richiesta:...

Table of Contents