E. Adjust Closing Position Magnet (See Fig. 3) - With
door in the closed position, use finger to slide Closed
Position Magnet so it aligns directly with the Reed
Switch.
Open Position
Magnet
Position Ring
F. Adjust Open Position Magnet - Use fingers to slide
L2
115Y
115/230VAC IN
L1
L2
230Y
U
MOTOR OUT
V
W
(Adjustments made in the shaded
area should be performed by
Authorized Factory Personnel.)
WARNING
Electric
Shock Risk
Norton® is a registered trademark of Yale Security Inc., an ASSA ABLOY Group company.
Copyright © 2015 Yale Security Inc., an ASSA ABLOY Group company. All rights reserved.
Reproduction in whole or in part without the express written permission of Yale Security Inc. is prohibited.
4. Final Electrical and Mechanical Setup Continued
Reed Switch
Closed Position
Magnet
Figure 3
TB501
NC
STATUS LEDS
NO
JMP503
H/O TM
H/O TQ
P1
M/DLY
120 HIGH VOLT POTENTIAL PRESENT. MAKE
SURE POWER IS TURNED OFF DURING
INSTALLATION PROCEDURE.
F cont. Open Position Magnet 180° from Open Position
Magnet.
G. Flip Breaker Switch to "RESET" to turn power on.
Jump terminals 1 and 2 (as shown in Fig. 2) to
activate door. Note open position of the door. Allow
door to close.
H. Use finger to readjust the Open Position Magnet to
desired door open position.
I. Repeat Step G to verify door open position.
J. Make all connections necessary for any accessories to
the 4-position Accessory Terminal (see Pages 10-11).
K. Make necessary adjustments to inverter (see Page 9).
Replace cover and cover screws.

Inverter Details

POT
M/DLY
OBSTR SENS
P1
11
COM
SNS
H/O TM
COM
H/O TQ
PB
K1
P2
K2
Inverter Adjustments:
·
Based on function
SW501
adjustment desired,
2
1
use table above to
determine which POT
ON
is to be adjusted.
OBSTR
SENS
P2
WARNING
Page 9
DESCRIPTION
Motor Delay on Opening
Obstruction Detection on Open
Closing Speed
Hold Open Time (5 - 30 Seconds)
Motor Torque at Hold Open
Position
Opening Speed
Dip Switch Settings
1. Door Mounting -
2. Push Recognition -
80-9357-0008-020 (Rev 3)
ASSA ABLOY
FUNCTION
CW - Increase
CCW - Decrease
CW - Increase
CCW - Decrease
CW - Increase
CCW - Decrease
CW - Increase
CCW - Decrease
CW - Increase
CCW - Decrease
CW - Increase
CCW - Decrease
ON - pull
OFF - push