Do you have a question about the Eleganza 3 and is the answer not in the manual?
Questions and answers
Dr . Omid
March 9, 2025
Hi Sir, i have imported 40 pcs Eleganza 3 bed more than 10 years ago.but now the plastic plate and internal part of the opening and closing bedside are broken. We need them as soon as possible . Attached photo.
Thanks
Dr. Omid
MIT co
Antidecubitus system, mattress replacement system series 2 (37 pages)
Summary of Contents for LINET Eleganza 3
Page 1
User manual and technical description Eleganza 3 Positionable hospital bed for acute care D9U001GZ5-0110 Version: 06 Publication date: 2019-11...
Page 2
LINET Americas, Inc., 10420-R Harris Oaks Blvd, Charlotte, NC-28269 ph.: 877-815-9895 fax: 704-248-5655 www.linetamericas.com Manufacturer: LINET spol. s r. o. Želevčice 5, 274 01 Slaný Tel.: +420 312 576 111 Fax: +420 312 522 668 E-mail: info@linet.cz http://www.linet.com Eleganza 3 Positionable hospital bed for acute care Author: LINET, s.r.o.
Safety Instructions ..........................9 Conditions of use ..........................10 Split siderails operations ........................10 3 Standards and Regulations ....................12 3.1 Eleganza 3 ............................... 12 3.2 Manufacturer ............................12 4 Electromagnetic compatibility .................... 12 5 Functioning .......................... 13 Correct Use ............................13 Incorrect Use ............................
Page 4
10.9.1 Castor Control Lever ........................... 32 10.10 Mobi-Lift® ............................33 10.10.1 Operation of Support Handles ...................... 33 10.11 Accessories ............................33 10.11.1 Lifting Pole ............................ 34 10.11.2 Infusion Stands ..........................34 10.11.3 Accessory Rails ..........................35 10.11.2 Holder for Dynamic Air Mattress Control Unit ................36 10.11.3 Safety Night Light ..........................
Symbols Warning Notices 1.1.1 Types of Warning Notices Warning notices are differentiated by the type of danger using the following key words: Caution indicates potential damage to property. Warning warns against bodily injury. Danger warns against potential mortal injury. 1.1.2 Structure of Warning Notices Type and source of danger!
Symbols and Labels on the Product Read instructions for use Thermal protection of transformer Only suitable for indoor use Protection against accidents due to electrical current - Applied part type B Safety isolating transformer, general CE Mark European Conformity Jack for attachment of conductor for potential equalisation Safe working load Warning against crushing or trapping...
Description of UDI label Fig. Serial Label (Eleganza 3 with scales) Address of manufacturer Manufacturing Date (Year-Month-Day) DI (Device Identifier) / GTIN (Global Trade Item Number) 1D Bar code GS1-128 (Serial Number) Symbols Configuration number Electrical Specification Serial Number PI (Product Identifier) 2D Bar Code (GS1 DataMatrix) DI+PI=UDI Fig.
Eleganza 3 bed should be left in its lowest position when the patient is unattended in order to reduce risk of injury due to falls! WARNING! Siderails of Eleganza 3 should be located in the „up“ position to reduce the risk of the patient accidentally slipping or rolling off the mattress! WARNING!
Eleganza 3 bed should not be used with bed hoists and bed lifts! WARNING! Incompatible siderails and mattresses can cause an entrapment hazard! WARNING! Inappropriate handling of the power supply cord, e. g. by kinking, shearing or other mechanical damages is hazardous!
Enable or disable functions on the handset using the supervisor panel as appropriate for the patient’s physical and mental state. Verify that the function is actually disabled. Never handle the mains plug with wet hands. Remove the mains cable by pulling on the plug only. ...
Standards and Regulations 3.1 Eleganza 3 The bed complies with the following standards: IEC 60601-1 CAN/CSA C22.2 NO. 60601-1 ANSI/AAMI ES60601-1 IEC 60601-1-2 IEC 60601-1-6 IEC 60601-2-52 ISO 14971 3.2 Manufacturer The manufacturer adheres to a certified quality management system in compliance with the following standards: ...
For information concerning uses other than those outlined in the “Correct Use” section above, please NOTE ® contact LINET Risk of injury or death due to use of incorrect equipment! Always conduct the risk assessments required for the selection of suitable equip- ment.
6 Scope of Delivery and Bed Variants Scope of Delivery Delivery: Upon receipt, check that the shipment is complete as specified on the delivery note. Notify the carrier and supplier about any deficiencies or damages immediately as well as in writing or enter them on the delivery note.
Setup Transport To avoid damage during transport, please observe the following guidelines: Ensure that no cables are run over when moving a bed. Ensure that the mains cable is attached with a hook (at the head end of the bed). ...
CPR Control Lever Unblocking the Backrest Handset Accessory Rail 5th Castor Foot Control Castor Diameter 150 mm with Main Control Lever Integrated Mattress Platform Extension Linen Holder Bed End Locking NOTE For safe, easy handling, LINET® recommends that two technicians assemble the bed. D9U001GZ5-0110_06...
Bed ends Fig. 2. Locking the Bed Ends Dismount the bed ends as follows: Unlock sleeve fittings 1. Pull bed ends from sleeve fittings. Install the bed ends as follows: Slide bed ends into sleeve fittings. Lock sleeve fittings 2.
The manufacturer takes no responsibility for any damage to the bed or battery caused by: Not following manufacturers user manual instructions Fitting batteries which are not approved by Linet Batteries fitted by an unqualified service organisation. To charge the battery: ...
Page 18
The LED indicates the battery’s charge status: Yellow LED Battery status Not lit Battery capacity is sufficient (charging completed) Battery is charging - continue charging until the LED is Short flashing (shortly lit, longer not lit) (circa 1.8 sec.) extinguished. In emergency cases, the battery can be used as a backup power source for a short period.
Removing the Bed from Service Remove the bed from service as follows: Disconnect the bed from the mains. Disconnect the ground wire. Deactivate the battery. Remove accessories. To prevent damage during storage: Pack or cover the bed and accessories. ...
10 Manipulation Risk of injury when adjusting the bed! Ensure that there are no body parts between the mattress platform elements and the mattress platform frame when adjusting the bed. Ensure that there are no body parts below the mattress platform frame before Warning adjusting the bed.
10.1 Supervisor Panel The supervisor panel is the main control element. The supervisor panel can be hung on the foot board if required. It is possible to hold the supervisor in the hand while operating. When not in use, store the supervisor panel in the built-in linen holder below the foot end. Fig.
10.1.1 Central STOP Button The central STOP button immediately interrupts all bed movements. When the central STOP button is pressed, the electronic stops all bed movements immediately. 10.1.2 Activating GO Button The GO button activates the keypads on all control panels. The GO button is included on a number of different control elements.
10.1.5 Position Buttons You can set the pre-programmed therapeutic and safety-related positions with the following buttons: Trendelenburg Position 17 Cardiac Chair Position 18 Examination Position 19 Bed Exit Position 20 CPR (Resuscitation) Position 21 Set the position as follows: ...
CPR (Resuscitation) Position The CPR position is for resuscitating the patient in an emergency. Settings after pressing position button 21: All mattress platform elements are retracted to their lowest position. The mattress platform is moved to the horizontal position. The bed moves into the CPR position within 30 seconds from any mattress platform position.
If the patient’s condition requires it, you can prevent the patient from adjusting the bed by: Disabling functions. NOTE An adapter for the handset is available. The adapter enables quick mounting and dismounting (e.g. replacing a defective handset, using the handset for another bed). 10.3 Satellite Panel The satellite panel is optional.
10.4 Foot Control The foot control is optional and allows you to set up the height of the bed with your feet. Fig. 7 Foot Control Lower Mattress Platform Foot Control Examination Position Foot Control Protection Frame against Unwanted Activation Raise Mattress Platform Foot Control Set the position as follows: ...
10.6 CPR Backrest Release Lowering the backrest too quickly can injure the patient! Ensure that the siderails are in the lowest position. Ensure that there are no body parts between the siderails and the backrest. Press the backrest down using the mattress guard handle only. WARNING The bed permits fast, mechanical lowering of the backrest for emergency resuscitation (CPR) procedures.
Turn the safety catches (frame) by 90°and push them in. 10.7 Siderails ® Eleganza 3 is equipped with four plastic siderails. If necessary, a retrofit with Eleganza Protector is possible. 10.7.1 Split Siderail The split siderails are components of the bed. A gas spring supports the operation of the split siderails.
Risk of injury due to patient falling out of bed! Ensure that the folded-up siderails are securely anchored . To check the stability, press against the siderails from the inside. WARNING To fold up the split siderail, pull up the split siderail until it latches. ...
10.9 Undercarriage Incorrect transport can damage the bed! Disconnect the bed from the mains before moving it. Store the mains cable in a safe place (plastic hook) on the bed during transport. Ensure that the castors are locked while the bed is stationary and prior to assembly, disassembly and maintenance.
10.10 Mobi-Lift® is optional. It serves as a support handle to enhance the patient’s safety when getting up. Mobi-Lift Mobi-Lift ® ® a support handle with a built-in height adjustment button. It allows the patient to raise and lower the mattress platform.
Ensure that the safety pin locks into place. A plastic grab handle with an adjustable strap shall be attached to the lifting pole. NOTE The date of manufacture is marked on the grab handle. LINET recommends that you replace the ®...
10.11.3 Accessory Rails The bed is optionally equipped with two accessory rails with plastic hooks. Load Capacity: Maximum load of 11 lbs without leverage Maximum load of hook pair 22 lbs Accessories for Hanging on the Accessory Rail: ...
10.11.2 Holder for Dynamic Air Mattress Control Unit Fig. 18 Holder for dynamic Air Mattress Control Unit The holder for the dynamic Air Mattress Control Unit is only to be used on bed ends. Suspend the holder for the dynamic Air Mattress Control Unit from the foot end. 10.11.3 Safety Night Light The night light is an optional accessory.
10.11.6 Writing Table Fig. 20 Writing Table Writing table to be placed in the openings on the bed ends. The writing table is made of ABS. Maximum load 6.6 lbs. If necessary, the writing table can be fixated vertically. 10.11.9 120 V Auxiliary Outlet Fig.
Page 36
Danger to life due to incorrect use! Do not use auxiliary outlet for life-sustaining equipment. Ensure that total leakage current in the chassis does not exceed 100 µA. Use only ''hospital grade'' or ''hospital only medical devices. ...
10.11.10 Bushing for Buck’s extension Risk of injury or material damage due to incorrect use! Never place any accessories (e.g. infusion stands, Protector etc.) except Buck’s extension into bushings for Buck’s extension. WARNING! The bed is delivered with bushings for Buck’s extension system.
Patient Weighing (WS17) 11.1 Weighing System Control Panel Fig. Weighing System Control Panel Display - weight value Indicator of Stabilized Scales Indicator of unit of weight (lb) Indicator of unit of weight (kg) Unit of weight switch button (kg/lb) ZERO button – zeroing or taring WEIGHT/CLEAR button - cancelling HOLD button Indicator of SafetyMonitor (ON/OFF)
Page 39
3) Displaying Display 1 shows normally actual weight. Indicator of stabilized scales 2 is lit at the same time when the stabilized weight value is displayed. To change between units of weight: Press button 5 to change unit of weight. When Indicator 3 is lit, pounds (lb) are set.
Page 40
6) BED EXIT ALARM BED EXIT ALARM is function monitoring patient´s presence on selected zone of the bed. Any weight drop of more than 20 kg will activate the acoustic alarm. During this alarm “BEA” and “ALA” alternate on the display 2 times each second.
Page 41
7) Bed Overload If the bed load is over 254,5kg: Overloading is signalized by long acoustic signal. The „Hi“ icon is displayed on the display. NOTE: If the bed is overloaded then it is impossible to position or manipulate with the bed until the overloading is removed.
Nurse call Optional functions for positionable Eleganza 3 beds: nurse call function bed exit function Control panel for nurse call activation: The control panel for nurse call activation is located on inside of head end siderails. When nurse call is activated, a signal is sent to nurse room.
12.1.1 Electrical ratings The system is designed for: maximum current 0.5 A standby, 1 A max. - short term maximum voltage 28.0 V 12.2 Operation Fig. 26 Nurse call control panel Microphone Nurse call button “listen” indicator “speak” indicator To activate the nurse call function: ...
(benzene, toluene, acetone, etc.). Clean the bed with a well-wrung, moist cloth. Clean electrical components carefully and allow them to dry fully. LINET ® recommends the following cleaning agents or their equivalent: Cleaning agents Manufacturer Schülke & Mayr...
13.1 Preparing for Cleaning Prepare for cleaning as follows: Put the mattress platform in the highest position. Adjust the back and thigh rests so that the reverse sides are accessible. Disable the function buttons on the control elements using the supervisor panel. ...
13.2.3 Complete Cleaning and Disinfection Clean the following bed parts: All of the control elements for adjusting the bed All handles Back and calf rest handles CPR release handle Head and foot boards Siderails (in highest position) ...
Maintenance Work Any service procedures must be performed only by qualified and certified service organization or person certified by Linet ® For information regarding the service or service documentation, and electrical contact schema name of the manufacturer. Manufacturer certified service organizations that are qualified to perform service and maintenance procedures for Linet beds ®.
15.1.3 Wear Check all bolts and tighten if necessary. Check all locking mechanisms. Check the bed for wear, scratches or rub marks. Eliminate the cause if necessary. Have any defective parts replaced. 15.2 Functioning Check that all bed adjustments reach the maximum position.
® Service Our responsive LINET® service partners will ensure your LINET® products are up and running when you need them. For more information on available service support and contract offerings, please contact us and ask for technical support. LINET®'s nationwide network of highly skilled service providers that are equipped to service and maintain your LINET®...
Environmental Protection Linet ® is aware of the importance of protecting the environment for future generations. Materials used in this product does not endanger the environment. They do not contain hazardous substances based on cadmium, mercury, asbestos, polychlorinated biphenyls, or CFCs. Noise and vibration are in accordance with the regulations applicable to the place of use.
18 Specifications 18.1 Mechanical Specifications Dimensions With Split Side rails Folded-up 223 cm x 105 cm Siderail lenght Split siderail 97,5 cm Foot siderail 52,5 cm Head siderail Recommended Mattress Size 208 cm x 96 cm Maximum Mattress Height 23 cm Height of Split Siderail above Mattress Platform 45 cm...
Battery T1.6 A L 250V for 220V primary lead Fuses T3.15 A L 250V for 100-127V primary lead NOTE Upon request, LINET ® can deliver hospital beds with electrical specifications that comply with regional standards (custom voltage, different mains plugs) Danger to life due to electric shock! ...
Mobile RF communication device (including end use devices like antenna cables and external antenna) should not be used closer than 30 cm (12 inches) from any part of this bed Eleganza 3, including cables specified by manufacturer. Otherwise this could lead to deterioration of functionality of this bed.
Page 55
Manufacturer instructions – electromagnetic emissions Emission test Compliance RF emissions Group 1 CISPR 11 RF emissions Class B CISPR 11 Harmonic emissions Class A IEC 61000-3-2 Voltage fluctuations / flicker emissions IEC 61000-3-3 Complies Manufacturer instructions – electromagnetic susceptibility Immunity Tests Compliance level ±...
Page 56
Table 1 – IMMUNITY to RF wireless communications equipment Test Immunity test frequency Band (MHz) Service Modulation level (MHz) Pulse modulation 380 - 390 TETRA 400 18 Hz FM ± 5 kHz 430 - 470 GMRS 460, FRS 460 deviation 1 kHz sine Pulse modulation 704 - 787 LTE band 13, 17...
Need help?
Do you have a question about the Eleganza 3 and is the answer not in the manual?
Questions and answers
Hi Sir, i have imported 40 pcs Eleganza 3 bed more than 10 years ago.but now the plastic plate and internal part of the opening and closing bedside are broken. We need them as soon as possible . Attached photo. Thanks Dr. Omid MIT co