WIRING DIAGRAM EXAMPLE: LUXOR + HEAT PUMP AND SYSTEM MANAGER
Supply voltage 24Vac;
Alimentazione 24Vac;
50Hz
50Hz
KEY:
A13
- System manager
A15-4 - Expansion kit with address "4"
Example of electrical connection LUXOR with System man-
ager and expansion kit.
To manage systems including LUXOR pellet boilers and Im-
mergas heat pump, it is possible to use the System manager
code 3.021522, in combination with Zone expansion kit code
3.021547.
In this case it will also be necessary to insert a flow switch (or a
contact thermostat) that indicates that the pellet boiler is active.
This contact must be connected to the expansion kit appropri-
ately configured with address "4" as shown above.
When the contact is closed, any generators present as AUDAX,
condensing boiler or electric resistances, remain forced on
stand-by.
46
Expansion Addresses
Contatto che segnala
Contact indicating the
l'attivazione di LUXOR
activation of LUXOR
(da ussostato o termostato
(from flow switch or
a contatto)
contact thermostat)