Technical Data - ATH-Heinl Flex Lift 30 Operating Instructions Manual

Hide thumbs Also See for Flex Lift 30:
Table of Contents

Advertisement

1.4

Technical Data

Type
Capacity
Lifting time (at 2.000 kg)
Lowering time (at 2.000 kg)
Electrical system
Control voltage
Motor
Fuse protection
Power cable
Protection class
Hydraulic pressure ²
Recommended hydraulic oil
Oil quantity
Noise level
Weight
²
The already factory-set hydraulic work pressure is adjusted to the maximum rating. The setting of
the pressure control valve may not be changed. Any changes to the settings could cause serious
damages.
If the nominal load could be not lifted please contact our service team.
Load distribution
Q
P1
P2
Load distribution
A
By changed distances the load capacity will be reduced.
® Copyright ATH-Heinl GmbH & Co. KG, All rights reserved / Misprints and technical changes reserved / As of: 2020-03
2,237 KW / 1450 Rpm
Summer: H-LPD 32 (z.B.: OEST H-LPD 32 DD L)
Total weight of vehicle
Manufacturer ATH-Heinl GmbH & CO.KG
- 6 -
ATH-Flex Lift 30
3000 kg
20 s
28 s
1 X 230V/50Hz
DC24V
3 C 16 A
Min. 3x 1,5mm²
IP 43
150-300 bar
Winter: H-LPD 22
Appr. 12 l
≤ 70 dB
590 kg
Max 3/5 x Q
Max 2/5 x Q
3/2
1.200 mm