Controls And Indicators; Inspections Prior To Starting; Starting And Stopping The Vacuum Cleaner; Operation - Nilfisk-Advance VHC110 Instructions For Use Manual

Hide thumbs Also See for VHC110:
Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 19
VHC110 - VHC120

Controls and indicators

1.
Manual filter shaker lever (standard deck)
2.
Vacuum gauge
3.
PullClean filter cleaning system (stainless steel deck)
4.
Air supply on/off valve

Inspections prior to starting

Before starting, check that:
The filters are installed;
The closing band is properly tightened;
the vacuum hose and tools have been correctly fitted into
the inlet (1, Fig. 5);
the liquid mechanical stop (9, Fig. 1) is properly installed
inside the liquid container (L version).
Lock the castor brakes (2, Fig. 5) before starting the
vacuum cleaner.
Do not use the device if the filters are faulty.

Starting and stopping the vacuum cleaner

Open the on/off valve (4, Fig. 3) to start vacuuming.
Close the on/off valve (4, Fig. 3) to stop vacuuming.
Liquid vacuuming stop (L version)
When the container is full, the liquid mechanical stop (9,
Fig. 1) turns off the vacuuming; the vacuum units remain
on.
Do not let the vacuuming unit running, after the liquid
stop has been activated.
I
GB
E
E
C447
Figure 3
WARNING!
WARNING!

Operation

Vacuum gauge (2): green zone (3), red zone (1)
When using the vacuum cleaner:, check the flow control:
when the vacuum cleaner is operating, the pointer of
the vacuum gauge must remain in the green zone (3)
to ensure that the speed of the intake air does not drop
below the safety value of 20 m/sec;
If the pointer is in the red zone (1) it means that the
speed of the air in the vacuum hose is less than 20 m/s,
and that the vacuum cleaner is not operating in optimal
conditions. Shake or replace the filter.
during normal operation conditions, close the vacuum
hose, the pointer of the vacuum gauge must switch from
the green zone (3) to the red zone (1).
WARNING!
When the vacuum cleaner is operating, always check
that the vacuum gauge pointer remains in the green
zone (3).
WARNING!
The air speed in the suction tube must not be less
than 20 m/s.
Condition indicated by the vacuum gauge pointer in
the green zone (3).
WARNING!
All vacuum cleaners can be used only with hoses
whose diameters comply with the specifications in
the "Technical Data" table.
WARNING!
Consult the "Troubleshooting" chapter if faults occur.
.
8
Figure 6
08/2018

Advertisement

Table of Contents
loading

This manual is also suitable for:

Vhc120

Table of Contents