11. Appx.1: Maintenance

11. Appx.1: Maintenance

11.1 Periodic Inspections

Periodic inspection of the following items is recommended.
[1] Are any of the screws on the terminal block loose? If loose, tighten them.
[2] Are any of the cables damaged or cracked? If the cables move with the machine, periodically inspect the cables
according to the working conditions.

11.2 Service Parts

A guide to the part replacement cycle is shown below. Note that these will differ according to the working conditions or
environmental conditions, so replace the parts if any abnormality is found. Contact Mitsubishi branch or your dealer for
repairs or part replacements.
Part name
MDS-EX-CVP
[1] Power smoothing capacitor:
The characteristics of the power smoothing capacitor will deteriorate due to the effect of ripple currents, etc. The
capacitor life is greatly affected by the ambient temperature and working conditions. However, when used
continuously in a normal air-conditioned environment (ambient temperature is an average of 40 °C or less), the
service life will be ten years.
[2] Relays:
Contact faults will occur due to contact wear caused by the switching current. The service life will be reached
after 100,000 cumulative switches (switching life) although this will differ according to the power capacity.
IB-1501587-A
Standard replacement time
Smoothing capacitor
Cooling fan
10,000 to 30,000 hours (2 to 3 years)
The standard replacement time is a
10 years
reference. Even if the standard
replacement time is not reached, the
part must be replaced if any
abnormality is found.