L-Acoustics K3i Owner's Manual page 20

Table of Contents

Advertisement

Rigging system description
K3i-BUMP is secured to the array with four M8x35 rigging screws and M8 nuts (provided). With K3i-LINK, the splay
angle with K3i can be set to 0°, 2.5°, 5°.
To calculate the site angle of the rst enclosure, subtract the splay angle from the site angle of K3i-BUMP.
2.5° splay angle
0° K3i-BUMP site angle
0-2.5 = -2.5° K3i site
angle
In Soundvision, the splay angles are labeled as follows (Elements panel):
angle in Soundvision
7.5°
10°
It is recommended to set a 0° splay angle (5° in Soundvision) between the rst K3i and K3i-BUMP.
By doing this, the K3i axis is parallel to K3i-BUMP.
Four holes are available on the central bar of the K3i-BUMP for site angle adjustments. Four additional holes are
available to add K3i-BAR to K3i-BUMP as an extension to increase the site angle.
1
A
B
20
5° splay angle
0° K3i-BUMP site angle
0-5 = -5° K3i site angle
splay angle
2.5°
2
3
4
A
B
2.5°
K3i owner's manual (EN) version 1.0

Advertisement

Table of Contents
loading

Table of Contents