Connecting the machine

4.3.1
Electrical connection
4.3.2
Water connection
The machine is to be connected to a tap of the pressure water pipe with
a ½ "DN 12 hose, suitable for pipe pressure.
With a flow pressure of minimum 2 bar up to maximum 10 bar the water
supply must be guaranteed according to the maximum volume flow of the
corresponding machine type.
4.3.3
Long-distance piping
The long-distance piping is to be carried out by a skilled fitter for oil and water
systems. Only components of the FRANK long-distance piping range are to be
used as the thermal and chemical constancy can be guaranteed for these parts
only.
4.3.4
High-pressure hose and spraying device
- 9 -
The machine must be connected to the mains in
accordance with the appropriate regulations
by a locally authorized senior electrician.
63 A slow blow fuses must be installed in the building
for the 30 kW version, 40 A slow fuses for the 18 kW
version.
For the installation and maintenance of the long-distance piping
special instructions have to be followed.
Only components which are approved by the manufacturer and
marked in accordance with regulations are to be used.
High-pressure hose and spraying device are to be connected
pressure-sealed to the machine. The high-pressure hose must not
be driven over, pulled excessively or twisted.