5.6

Works setting

The machine has been set and tested according to the technical data
under section 2.
The works setting and testing has been done under the following conditions:
Ambient temperature (Air temperature):
Medium air pressure:
5.7

Commissioning

5.7.1 Initial commissioning
Compare the technical data on the machine plate to the technical data of this
operating instructions.
Check oil level of the high-pressure pump.
Fill up cold water tank and hot water tank. For this purpose open tap of the
water supply pipe and set main and emergency switch to "1".
Operate and deaerate the machine with cold water, without the adding of cleaning
agents for about 1 minute, at zero pressure. For this purpose:
- set turning button of the regulating thermostat right back to the stop.
- set dosing valve button to "0"
- set main and emergency switch to "1"
- actuate button switch on the control cabinet at the washing site.
Thereupon:
- set main and emergency switch to "O".
- connect spray lance and spray gun to the high-pressure hose in a pressure-
sealed manner.
5.7.2 Rated value settings
Set operating temperature on the turning button of the regulating thermostat.
Set the dosing of the cleaning and preserving agents on the dosing valve button
according to the table below: