Some examples:
To change DMX channel 5 to value 200:
ASCII: (tag, f value)
/dgmk2/4\00\00\00\00,f\00\00CH\00\00
HEX:
2f 64 67 6d 6b 32 2f 34 00 00 00 00 2c 66 00 00 43 48 00
00
To change DMX channel 121 to value 50:
ASCII:
/dgmk2/120\00\00,f\00\00BH\00\00
HEX:
2f 64 67 6d 6b 32 2f 31 32 30 00 00 2c 66 00 00 42 48 00
00
Web: RDM Tools
RDM tools page, with DMX ports set as output, can be
used to discover RDM device, and allow user to access
and control below 10 PIDs without relying on external
RDM controller. Each RDM device, has its' own set of
functions and buttons, so multiple devices can be
handled easily. Clicking on the device ID, opens a new
page to handle this device separately.
PIDs
1.
DEVICE INFO
2.
DMX START ADDRESS
3.
DMX PERSONALITY
4. LAMP ON MODE
5.
DEVICE DESCRIPTION
6. MANUFACTURING LABEL
7.
DEVICE LABEL
8. FACTORY DEFAULTS
9. SOFTWARE VERSION
10.
SUPPORTED PARAMETERS
7
Web: RDM Sensors
RDM Sensors page, allows discovering all RDM devices and
monitoring all sensors supported by RDM tool. Examples
include: Temperature, Current and, Voltage sensors.
Values can be exported, or emailed at intervals set using
the settings page. Sensors layout can be saved and
loaded, to minimize any delay in discovering them again
and again.
Firmware Update
You can update the firmware on the Datagate Mk2, via the
web browser. Firmware files are available on the ENTTEC
website.
Always check your Datagate Mk2's hardware revision, (Rev
A, B or C on the device homepage, to ensure you are
downloading firmware that is compatible with your
device).
Download the firmware to your desktop and then follow
instructions on the Datagate Mk2's Settings page.
Note: While the firmware is being updated, please do not
power off the unit, please wait until the web-page is
processing. (up-to 5 minutes)
If the web-page does not refresh automatically, please
open the home page on the browser manually, and verify
that the update has succeeded.