Enttec DATAGATE MK2 Quick Start Manual page 5

Hide thumbs Also See for DATAGATE MK2:
Table of Contents

Advertisement

Web: Profile Editor
Create a new profile or edit an existing one using the
profile-editor. Opens up in a new page in your web
browser. Select a module on the left and the right panel
will provide help about that panel. Connect a module to
another using wires from one point to another.
The direction of the wire (arrow) is important, the
arrow signifies output, and reflects the flow of data.
Web: Profile Modules
Each profile is made up of two or more connected
Modules or Actions. The relationship between them
forms the layout of the data flow within the profile.
The following modules are available:
The DMX port
represents one of the physical ports on
the rear of this unit, select which port you want to use by
using the drop down.
Rate: refresh rate to send DMX (frames per
second)
Break: Break time (micro sec) between each DMX
frame (default is 200)
MAB: Mark After Break time (micro sec) default is
52
Channels: Number of channels to send in 1
Universe (default is 512)
Limitation: Same DMX port cannot be re-used in the same
profile.
5
Art-Net Stream:
"Send IP address": is the destination
address used when the stream is sending data only
(Unicast).
Use the left node to connect a stream with ArtRDM to a
physical DMX port (up to the first 256 ArtNet universes).
Use the right node for ArtNet without ArtRDM.
ESP Stream
:
ENTTEC Show protocol DMX over Ethernet
stream (ESP). IP address is the destination address used
when the stream is sending data only.
Kinet Stream
: For example: You can connect Kinet Stream
to an Art-Net Stream to convert and output as Art-Net. (Kinet
stream is supported as input only)
Streaming ACN
:
"IP address" is the destination address
used when the stream is sending data only
(default is disabled = 0.0.0.0)
DMX Generator
:
Define your own custom DMX Channel
values and assign the selected ones.
Snapshot feature can be used to capture values from an
input stream. All modifications can be done using the DMX
Grid Page.
Quick Start Manual
Datagate MK2 70044
For latest version visit:
www.enttec.com
ID: 2691

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the DATAGATE MK2 and is the answer not in the manual?

Questions and answers

This manual is also suitable for:

70044

Table of Contents