ETC Installation Guide
ColorSource PAR v1.7
Environment
The ColorSource PAR operates in ambient temperatures of 0°C–40°C and
comes with a variable-speed fan. The ColorSource PAR is for indoor use only.
Maximum recommended ambient operating temperature: Ta = 40°C
•
(104°F)
Maximum anticipated external surface temperature at 40°C ambient:
•
Tmax = 80°C (176°F)
External temperatures after 5 minutes of full-brightness operation at
•
25°C (77°F) ambient: 30°C (86°F)
External Temperature (steady state achieved) at 25°C (77°F): 41°C
•
(106°F)
Electrical
Operates between 100 V and 240 VAC at a frequency of 50/60 Hz.
•
Maximum power consumption is 120 W.
•
Up to 9 luminaires (15 A max) may be linked via power thru connector
•
(10 luminaires total per circuit) when used with an R20 Relay Module
or Unison Echo Relay Panel. Consult breaker trip curves when used
with other equipment. Requires power from a non-dimmable source.
Inrush:
•
120 V: 35 A (first half-cycle)
-
240 V: 49 A (first half-cycle)
-
Typical Power Consumption
Idle
Direct at Full
ColorSource PAR
100 V
Power
Current
1.22 W
0.03 A
107 W
1.07 A
120 V
Power
Current
1.21 W
0.03 A
106 W
0.88 A
Page 4 of 12
230 V
Power
Current
1.14 W
0.03 A
104 W
0.46 A