GiBiDi TAIMEN T6 Instructions For Installation Manual page 41

Electromechanical gearmotors
Hide thumbs Also See for TAIMEN T6:
Table of Contents

Advertisement

Available languages

Available languages

TAIMEN
dt
DETENSIONING
ANTI-
Af
CRUSHING
0f
Detensioning in closing disabled.
Detensioning in closing enabled. After the door has been completely closed, the
0n
motor moves back a little to reduice system tension.
Learn
dt
Confirm
Amperometric threshold of the motor, the default value is calculated from the
control unit during the travel learning.
The more you increase this value, the more the operator pushes before making the
anti-crushing manoeuvre.
A low value needs a door in perfect conditions and well balanced.
Operation:
It is disabled in the last part of the motion (near opening and closing stops)
Ÿ
Its intervention in closing causes the immediate inversion of the motion
01
Ÿ
decelerating till a complete opening and, if enabled, will make the automatic
closing.
Its intervention in opening causes the stop of the movement and the control
Ÿ
unit waits for a command.
N°3 interventions in succession, before a complete closing, cause the stop of
Ÿ
the movement and the control unit waits for a command.
Learn
Af
Confirm
Learn
Confirm
/
0f
Learn
Confirm
Learn
Confirm
/
01
Learn
Confirm
Learn
0n
Confirm
Learn
05
Confirm
41