PARAMETERS
The DEFAULT settings are indicated by the grey box
Display
Function
5b
PHOTOCELLS
RS TERMINAL
r5
FUNCTION
Status
SB input disabled (terminal 4).
0F
SB input enabled, install the photocells
Operation:
Input enabled only during closing phase.
0n
Stop the motion and reverse completely opening.
If intercepted in pause, charge again the pause time.
If enabled, allows the fast closing (see menu
SB enabled in opening and closing (terminal 4).
Operation:
Input enabled both in opening and closing.
OC
If intercepted, stops the motion till it is not freed.
When released, the motion starts again in opening.
If intercepted in pause, charge again the pause time.
Learn
Confirm
5b
Learn
Confirm
Terminal RS disabled (terminal 5)
0F
Terminal
RS works as 8k2 safety edge, install the device
Operation during closing movement:
reverse the motion for 2s, when the contact is restored, open completely again
and, if the automatic closing is enabled, will close automatically again.
N°3 interventions in succession, before a complete closing, cause the stop of
5e
the movement and the control unit wait for a command. The reverse movement
is done at 50% of maximum speed.
Operation during opening movement:
stop the motion and the control unit waits for a command.
Terminal
RS works as 8k2 stop, install the device
Operation during closing movement:
5T
stop the motion and the control unit waits for a command.
Operation during opening movement:
stop the motion and the control unit waits for a command.
Description
(terminal 4)
.
fc
)
Learn
Learn
/
0F
0n
Confirm
Confirm
(terminal 5)
TAIMEN
Learn
/
OC
Confirm
(terminal 5)
.
.