Technical Specifications; Assembly; Operation Of The Keypad; Description Of The Elements - GSE 16A Manual

Fan controller
Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 18
Operating voltage: 230V / 50Hz
Depending on the country the maximum power rating of the power-cord is variable:
VDE L typ max: 16A, Schuko
VDE F type max: 16A, France
VDE E type max:13A, Switzerland
VDE U type max 13A, England
Loading of the individual outputs:
Intake fan max:
Exhaust fan max :
Exit 1 max:
Exit 2 max:
The sum of all the currents can not exceed prescribed maximum current of the country socket!
Mount the 16A fan controller with the included mounting bracket to a non-flammable surface such
as brick concrete and never on wood, plastic carboard, etc. Make sure that on your choice of the
place have sufficient ventilation in the location and the heat can be dissipated. Avoid small
unventilated rooms or cabinets. Improper installation will result a overheating of the controller!
The controller is operated by four menu keys.
With the arrow keys UP and DOWN the various menu lines can be selected. Press ENTER to
go one level deeper into the submenu and SAVE / EXIT one level back.
If settings get changed with the two arrow keys you don't have to confirm with ENTER, the values
get stored with SAVE / EXIT!
All values get stored in an internal memory and are also after a power failure or prolonged
disconnection available. Time and date have a back-up capacitor which runns about 72 hours. After
this time they have to be setted again.
1. Connection for exhaust fan
2. Connection for intake air fan
3. Programmable exit 1
4. Programmable exit 2
5. Temperature LED
6. Exit 1 LED
7. Humidity LED
8. Day / night LED
9. Alarm LED
10. Exit 2 LED
16A Fan controller
Technical specifications
10A 2300W cos 1
10A 2300W cos 1
10A 2300W cos 1
10A 2300W cos 1

Assembly

Operation of the keypad

Description of the elements

11. UP arrow
12. DOWN arrow
13. SAVE / EXIT
14. ENTER
15. Powersupply
16. Sensor cable for temperature
and humidity (only gases)
17. Sensor cable for temperature
(liquids and gases)
18 LCD display with 2x16
characters
19 USB LED
20. USB port
EN
17

Advertisement

Table of Contents
loading

Table of Contents