Size 24K - 208/230V - Carrier 38MHRC Service Manual

Outdoor unit single zone ductless system sizes 09 to 24
Hide thumbs Also See for 38MHRC:
Table of Contents

Advertisement

REFRIGERATION CYCLE DIAGRAMS (CONT)
Pressure measurement
Gauge attaching port
Vaccum pump connecting port
Deoxidized copper pipe
{
Outer dia:
0.626
in(
15.9
mm)
4-way valve
18
INDOOR UNIT
Indoor heat
exchanger
Cross flow fan
Deoxidized copper pipe
{
Outer dia:
0.375
in(
9.52
mm)
Sectional shape
of insulation
Muffler
Muffler
TP
Compressor
T4
Outdoor heat
exchanger
T3
Propeller fan
OUTDOOR UNIT
Fig. 15 — Size 24K - 208/230V
Specifications subject to change without notice.
T2
T1
Pulse Modulating
Valve at liquid side
Strainer
NOTE: Gas leak check position
Refrigerant flow (Cooling = solid arrow)
Refrigerant flow (Heating = dashed arrow)
Max :
164
ft(
50
m)
Min :
10
ft(
3
m)
Pre-charged:
25
ft(
7.5
m)
Charge :
0.32
oz/ft
SG-38MHRC-01