Download Print this page

Advertisement

Quick Links

40MAQ / 38MAQ
619PB / 538PR
Sizes 09 to 30
A NOTE ABOUT SAFETY
GENERAL
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
PART NAMES
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
DISPLAY PANELS
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
REMOTE CONTROL
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
REMOTE CONTROL FUNCTIONS
CLEANING, MAINTENANCE AND TROUBLESHOOTING
Please read this Owner's Information Manual carefully before installing and using this appliance
and keep this manual for future reference.
For your convenience, please record the model and serial numbers of your new equipment in the
spaces provided. This information, along with the installation data and dealer contact information,
will be helpful should your system require maintenance or service.
UNIT INFORMATION
Model # ___________________________________
Serial # ___________________________________
INSTALLATION INFORMATION
Date Installed _____________________________
Owner's Manual
TABLE OF CONTENTS
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
NOTE TO EQUIPMENT OWNER:
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
DEALERSHIP CONTACT INFORMATION
Company Name: _________________________________
Address:_________________________________________
________________________________________________
Phone Number:__________________________________
Technician Name:_________________________________
________________________________________________
PAGE
2
2
3
4
5
6 - 7
8 - 9

Advertisement

loading

Summary of Contents for Carrier 538PR

  • Page 1 40MAQ / 38MAQ 619PB / 538PR Sizes 09 to 30 Owner’s Manual TABLE OF CONTENTS PAGE A NOTE ABOUT SAFETY ................. . .
  • Page 2 A NOTE ABOUT SAFETY GENERAL The high wall fan coil unit provides quiet, maximum comfort. In Any time you see this symbol in manuals, instructions and on addition to cooling and/or heating, the high wall fan coil unit the unit, be aware of the potential for personal injury. There are matched with an outdoor condensing unit will filter and three levels of precaution: dehumidify the air in the room to provide maximum comfort.
  • Page 3 PART NAMES ■ Indoor 1. Front panel 2. Air Inlet 3. Display 4. Air Filter 5. Horizontal airflow grille 6. Vertical air flow louver 7. Interconnecting tubing 8. Control and power wiring to indoor unit 9. Service valves 10. Remote control 11.
  • Page 4 DISPLAY PANELS SELECTED TEMPERATURE / SELF-DIAGNOSTIC CODES indicator DEFROST indicator Illuminates when the coil is warming up to prevent cold blow or when the unit goes into defrost mode. OPERATION indicator This indicator flashes once per second after power is on and illuminates when the unit is in operation.
  • Page 5 REMOTE CONTROL ON/OFF SH ORT MODE TIMER ON T EMP FA N TIMER OFF SLEEP SWI NG DI RECT TURBO Fig. 4 - Remote Control Remote Control Operation - Quick Start CAUTION NOTE: When transmitting a command from the remote control to the unit, be sure to point the control toward the right side of the EQUIPMENT DAMAGE HAZARD unit.
  • Page 6 REMOTE CONTROL FUNCTIONS Selecting the Horizontal Direction Louver Position In order to optimize comfort, the horizontal louver will operate in a preset range as shown in the figure below. Pressing the On/Off Button When the air conditioner is not in operation, the remote control will display the last set point and mode.
  • Page 7 Timer Function - The unit will shut off 5 hours after setting the SLEEP mode. - The SLEEP mode will be cancelled if either the “Mode”, TIMER ON (to start the unit) and TIMER OFF (to stop the unit) “TEMP”, “Fan”, “Timer”, or “On/Off” buttons on the can be used separately or together.
  • Page 8 CLEANING, MAINTENANCE AND TROUBLESHOOTING Indoor Unit Front Panel CAUTION To clean the front panel on the indoor unit, wipe the outside with a soft, dry cloth. ELECTRICAL SHOCK HAZARD Preparing for Extended Shutdown Period Failure to follow this caution may result in personal injury Clean the filters and reposition them in the unit.
  • Page 9 Table 1—Periodic Maintenance INDOOR UNIT EVERY 3 MONTHS EVERY 6 MONTHS EVERY YEAR Clean Air Filter* Change Remote Control Batteries OUTDOOR UNIT EVERY 3 MONTHS EVERY 6 MONTHS EVERY YEAR Clean Outdoor Coil from Outside Clean Outdoor Coil from Inside† Blow Air Over Electric Parts†...